During night time or power failure, Prostar hybrid bi-directional solar inverter 10kW 48v will automatically extract power from battery. In this way, it will reduce the dependence on the utility.
MixSolar 3 phase hybrid bi-directional solar inverter 10kW 48v is a flexible and intelligent hybrid inverter which utilizes solar power, AC utility, and battery power source to supply continuous power. It’s a simple and smart solar power storage system for home users to either store energy into battery and wait for night time usage or use for self-consumption first depending on demands. Priority for power source can be programmed and set up through smart software.
During night time or power failure, Prostar hybrid bi-directional solar inverter 10kW 48v will automatically extract power from battery. In this way, it will reduce the dependence on the utility.
In comparison with conventional grid-tie inverter, MixSolar hybrid bi-directional solar inverter 10kW 48v is able to not only feed-in power to grid but also store solar power to battery for future usage and directly power to the loads.
MixSolar hybrid bi-directional solar inverter can save money by using battery energy frst when PV energy is low. Until battery energy is low, will extract AC power from the grid.
MixSolar hybrid bi-directional solar inverter can operate as an off-grid inverter to provide continuous power even without the grid. It’s perfect power solution for remote regions or temporary AC power source such as camping or flea market.
Model | MixSolar MIS10KW |
PHASE | 3-phase in/3-phase out |
Max. PV INPUT POWER | 14850W |
Rated Output Power | 10000W |
Maximum Charging Power | 9600W |
Dimension, D x W x H (mm) | 168 x 500 x 622 |
Net weight (kgs) | 45 |
GRID-TIE OPERATION | |
PV INPUT (DC) | |
Nominal DC Voltage/Max. DC Voltage | 720 VDC/900 VDC |
Start-up Voltage/Initial Feeding Voltage | 320 VDC/350 VDC |
MPP Voltage Range | 400 VDC~800 VDC |
Number of MPP Trackers | 2/2×18.6A |
Maximum Input Current | |
GRID OUTPUT (AC) | |
Nominal Output Voltage | 230 VAC (P-N)/400 VAC (P-P) |
Output Voltage Range | 184 – 265 VAC* per phase |
Nominal Output Current | 14.5A per phase |
Power Factor | >0.99 |
EFFICIENCY | |
Maximum Conversion Efficiency (DC/AC) | 96% |
European Efficiency@Vnominal | 95% |
OFF-GRID OPERATION | |
AC INPUT | |
AC start-up Voltage / Auto Restart Voltage | 120-140 VAC per phase/180 VAC per phase |
Acceptable Input Voltage Range | 170-280 VAC per phase |
Max. AC Input Current | 40A |
PV INPUT (DC) | |
Max. DC Voltage | 900 VDC |
MPP Voltage Range | 400 VDC~800 VDC |
Number of MPP Trackers/Max. Input Current | 2/2×18.6A |
BATTERY Mode Output (AC) | |
Nominal Output Voltage | 230 VAC (P-N)/400 VAC (P-P) |
Output Waveform | Pure Sinewave |
Efficiency (DC to AC) | 91% |
HYBRID OPERATION | |
PV INPUT (DC) | |
Nominal DC Voltage/Max. DC Voltage | 720 VDC/ 900 VDC |
Start-up Voltage/Initial Feeding Voltage | 320 VDC/ 350 VDC |
MPP Voltage Range | 400 VDC~800 VDC |
Number of MPP Trackers/Max. Input Current | 2/2×18.6A |
GRID OUTOUT (AC) | |
Nominal Output Voltage | 230 VAC (P-N)/400 VAC (P-P) |
Output Voltage Range | 184-264.5 VAC* per phase |
Nominal Output Current | 14.5A per phase |
AC INPUT | |
AC Start-up Voltage/Auto Restart Voltage | 120-140 VAC per phase/ 180 VAC per phase |
Acceptable Input Voltage Range | 170-280 VAC per phase |
Max. AC Input Current | 40A |
BATTERY MODE OUTPUT (AC) | |
Nominal Output Voltage | 230 VAC (P-N)/400 VAC(P-P) |
Efficiency (DC to AC) | 91% |
BATTERY& CHARGER | |
Nominal DC Voltage | 48 VDC |
Max. Charging Current | Default 60A, 10A-200A (Adjustable) |
INTERFACE | |
Communication Port | RS-232/USB and CAN Interface |
Intelligent Slot | Optional SNMP, Modbus and AS-400 cards available |
ENVIRONMENT | |
Humidity | 0~90% RH (Non-condensing) |
Operating Temperature | -10 to 55 °C |
Altitude | 0-1000 m** |
*These figures may vary depending on different AC voltage and country requirements.
**Power derating 1% every 100m when altitude is over 1000m.