Guangdong Prostar New Energy Technology Co., Ltd.

PET1101+Li 1000VA lithium UPS 48v single phase double conversion

Prostar PET1101+Li is a 1000VA lithium UPS for users who need efficiency, lifespan, and power protection in environments with power fluctuations. It supports 48V LiFePO4 batteries, uses online double conversion, delivers 0ms transfer time, outputs pure sine wave, and includes intelligent battery management. This 1000VA lithium UPS supplies power for servers, network equipment, security systems, telecom devices, and industrial control applications.

Power Instability & Traditional VRLA Limitations in Critical Operations

Data edge nodes, medical diagnostic units, and industrial automation control systems require power quality. Mains grid fluctuations—voltage sags, surges, harmonic distortion, and blackouts—cause risks:

Data Corruption & Hardware Failure

Switchover delays in offline or line-interactive UPS systems produce micro-cuts. These micro-cuts reset servers or industrial PLCs.

High Total Cost of Ownership (TCO)

Legacy Lead-Acid (VRLA) batteries have a lifespan of 2–3 years, weigh more, recharge slowly, and react to temperature changes.

Space & Weight Constraints

Traditional tower UPS units with lead-acid batteries weigh more and occupy space. This creates problems for remote or space-limited deployments.

PET1101+Li 1000VA Lithium UPS with 48V LiFePO4 Battery

 

Product Key Features

Online Double Conversion Technology (VFI)

The inverter supplies power continuously. The UPS isolates the load from grid disturbances. It protects against outages, voltage changes, surges, and noise.

Unity Power Factor

1000VA lithium UPS operates at PF=1.0. It delivers 1000W active power. It supports modern IT and electronic equipment at full load capacity.

48V LiFePO4 Lithium Battery Compatible

This UPS works with 51.2V LiFePO4 battery systems and communicates with BMS. It extends battery lifespan, increases reliability, and lowers TCO.

Zero Transfer Time (0ms)

Online UPS switches between mains and battery instantly. This prevents downtime and maintains operation of devices.

Pure Sine Wave Output

The UPS produces AC power with THDv <3% for linear loads. It powers electronics, servers, and communication equipment without disruption.

Smart Battery Management System (BMS)

The system includes over-charge, over-discharge, over-current, short-circuit, and temperature protection. It increases battery safety, reliability, and service life.

Adjustable Charging Current (1A-20A)

You can control charging through UPS settings. You can match charging performance to battery capacity and application.

Why Choose a 1000VA Lithium UPS Instead of Traditional UPS?

A lithium UPS offers advantages over conventional VRLA UPS systems.

Comparison Lead-Acid UPS PET1101+Li Lithium UPS
Battery Type VRLA LiFePO4
Battery Voltage Usually 24V/36V 48VDC
Cycle Life Around 300-500 cycles Thousands of cycles
Maintenance Frequent replacement Low maintenance
Charging Speed Slow Faster charging capability
Energy Density Lower Higher
Battery Management Basic Intelligent BMS Protection

 

 

Technical Specifications

General Specifications

Parameter Specification
Model PET1101+Li
Capacity 1000VA / 1000W
Topology Online Double Conversion
Phase Single Phase
Form Factor Tower
Dimension (D×W×H) 290×145×238 mm
Net Weight 5.2 kg

Input and Output Performance

Parameter Specification
Input Voltage Range Nominal Voltage ±15%
Frequency Range 50Hz: 44-56Hz / 60Hz:54-66Hz
Input Power Factor ≥0.99
Input THDi <6%
Output Voltage 208/220/230/240VAC Selectable
Voltage Regulation ±1% (Battery Mode)
Output Waveform Pure Sine Wave
Transfer Time 0ms
Battery Frequency Accuracy 50Hz/60Hz ±0.1%
Crest Factor 3:1

Battery and Communication

Parameter Specification
Battery Type LiFePO4 Lithium / Lead Acid
Nominal Battery Voltage 48VDC (51.2VDC LiFePO4)
Charging Current 5A Default, Adjustable 1-20A
Charging Mode CC/Floating or CC/CV/Floating
Battery Protection Over-charge, Over-discharge, Over-current, Short Circuit, Temperature Protection
Communication Ports USB / RS232 / RS485
Smart Slot SNMP / Dry Contact Optional
BMS Protocol Pylontech RS485 & CANbus

Application Scenarios

Edge Computing

The UPS supplies backup power to edge servers. It delivers pure sine wave and zero transfer delay.

Medical Equipment & Diagnostics

48V UPS protects laboratory devices from micro-cuts and noise.

Telecom & Remote Network Cabinets

The 48V DC battery architecture recharges in 2 hours. It operates for 8–10 years in remote enclosures.

Frequently Asked Questions (FAQ)

A 1000VA lithium UPS utilizing LiFePO4 technology offers up to 3 times longer operational lifespan, significantly faster recharge times, and a 60% reduction in physical weight. It eliminates frequent battery replacements, drastically cutting long-term maintenance costs.
"0ms transfer time" means there is zero delay when switching from AC utility power to battery mode during an outage. In an online double conversion architecture, the inverter continuously feeds the output load from the internal DC bus, preventing any voltage interrupt or power drop.
Yes. While optimized for 51.2V LiFePO4 chemistry with smart BMS integration, the PET1101+Li charger and management system support selectable profiles for standard 48V Lead-Acid battery configurations as well as adjustable charging currents from 1A to 20A.
The unit features an input power factor of ≥0.99 and harmonic distortion (THDi) of less than 6%. This ensures that the UPS draws clean current from the utility grid without feeding reactive power or harmonic pollution back into your system.