Prostar PET1101+Li is a 1000VA lithium UPS for users who need efficiency, lifespan, and power protection in environments with power fluctuations. It supports 48V LiFePO4 batteries, uses online double conversion, delivers 0ms transfer time, outputs pure sine wave, and includes intelligent battery management. This 1000VA lithium UPS supplies power for servers, network equipment, security systems, telecom devices, and industrial control applications.
Power Instability & Traditional VRLA Limitations in Critical Operations
Data edge nodes, medical diagnostic units, and industrial automation control systems require power quality. Mains grid fluctuations—voltage sags, surges, harmonic distortion, and blackouts—cause risks:
Data Corruption & Hardware Failure
Switchover delays in offline or line-interactive UPS systems produce micro-cuts. These micro-cuts reset servers or industrial PLCs.
High Total Cost of Ownership (TCO)
Legacy Lead-Acid (VRLA) batteries have a lifespan of 2–3 years, weigh more, recharge slowly, and react to temperature changes.
Space & Weight Constraints
Traditional tower UPS units with lead-acid batteries weigh more and occupy space. This creates problems for remote or space-limited deployments.

Product Key Features
Online Double Conversion Technology (VFI)
The inverter supplies power continuously. The UPS isolates the load from grid disturbances. It protects against outages, voltage changes, surges, and noise.
Unity Power Factor
1000VA lithium UPS operates at PF=1.0. It delivers 1000W active power. It supports modern IT and electronic equipment at full load capacity.
48V LiFePO4 Lithium Battery Compatible
This UPS works with 51.2V LiFePO4 battery systems and communicates with BMS. It extends battery lifespan, increases reliability, and lowers TCO.
Zero Transfer Time (0ms)
Online UPS switches between mains and battery instantly. This prevents downtime and maintains operation of devices.
Pure Sine Wave Output
The UPS produces AC power with THDv <3% for linear loads. It powers electronics, servers, and communication equipment without disruption.
Smart Battery Management System (BMS)
The system includes over-charge, over-discharge, over-current, short-circuit, and temperature protection. It increases battery safety, reliability, and service life.
Adjustable Charging Current (1A-20A)
You can control charging through UPS settings. You can match charging performance to battery capacity and application.
Why Choose a 1000VA Lithium UPS Instead of Traditional UPS?
A lithium UPS offers advantages over conventional VRLA UPS systems.
| Comparison | Lead-Acid UPS | PET1101+Li Lithium UPS |
| Battery Type | VRLA | LiFePO4 |
| Battery Voltage | Usually 24V/36V | 48VDC |
| Cycle Life | Around 300-500 cycles | Thousands of cycles |
| Maintenance | Frequent replacement | Low maintenance |
| Charging Speed | Slow | Faster charging capability |
| Energy Density | Lower | Higher |
| Battery Management | Basic | Intelligent BMS Protection |
Technical Specifications
General Specifications
| Parameter | Specification |
| Model | PET1101+Li |
| Capacity | 1000VA / 1000W |
| Topology | Online Double Conversion |
| Phase | Single Phase |
| Form Factor | Tower |
| Dimension (D×W×H) | 290×145×238 mm |
| Net Weight | 5.2 kg |
Input and Output Performance
| Parameter | Specification |
| Input Voltage Range | Nominal Voltage ±15% |
| Frequency Range | 50Hz: 44-56Hz / 60Hz:54-66Hz |
| Input Power Factor | ≥0.99 |
| Input THDi | <6% |
| Output Voltage | 208/220/230/240VAC Selectable |
| Voltage Regulation | ±1% (Battery Mode) |
| Output Waveform | Pure Sine Wave |
| Transfer Time | 0ms |
| Battery Frequency Accuracy | 50Hz/60Hz ±0.1% |
| Crest Factor | 3:1 |
Battery and Communication
| Parameter | Specification |
| Battery Type | LiFePO4 Lithium / Lead Acid |
| Nominal Battery Voltage | 48VDC (51.2VDC LiFePO4) |
| Charging Current | 5A Default, Adjustable 1-20A |
| Charging Mode | CC/Floating or CC/CV/Floating |
| Battery Protection | Over-charge, Over-discharge, Over-current, Short Circuit, Temperature Protection |
| Communication Ports | USB / RS232 / RS485 |
| Smart Slot | SNMP / Dry Contact Optional |
| BMS Protocol | Pylontech RS485 & CANbus |
Application Scenarios
Edge Computing
The UPS supplies backup power to edge servers. It delivers pure sine wave and zero transfer delay.
Medical Equipment & Diagnostics
48V UPS protects laboratory devices from micro-cuts and noise.
Telecom & Remote Network Cabinets
The 48V DC battery architecture recharges in 2 hours. It operates for 8–10 years in remote enclosures.
Frequently Asked Questions (FAQ)
The Articles You may Like
- Why Every Server Room Needs a Rackmount Uninterruptible Power Supply
- Stand-alone power system – Wikipedia
- How to Size Modular UPS for Server Room Without Overspending
- Industrial UPS Design: When to Use an Autotransformer vs. Isolation Transformer
- Prostar Power: Delivering Reliable Power Solutions
- Choosing the Right UPS for Telecom Base Station Power Backup