Prostar PET3340 best dsp based parallel online 40kva ups 3 phase can deliver continuous, clean, and reliable power for mission-critical applications. Built with advanced Digital Signal Processing (DSP) technology, PET3340 online 40kva ups 3 phase guarantees maximum power protection. It uses true double-conversion online architecture to deliver efficiency and scalability for modern power-demanding environments.
The 40kva upss 3 phase adopts cutting-edge DSP control technology. This technology enables high-speed data processing and precise voltage regulation. It allows rapid system response to load or input fluctuations. This intelligent control enhances overall system stability, improves reliability, and ensures consistent performance under harsh electrical conditions.
The PET3340 3 phase 40kva ups is equipped with multiple protection mechanisms. These include overload, short-circuit, over-temperature, and battery protection. These features ensure safe and reliable operation. The Emergency Power Off (EPO) function enhances operational safety. The intuitive LCD interface provides real-time system status. It also allows for easy parameter configuration.

40kVA UPS 3 Phase Key Features
Pure Double Conversion Online Technology
Provides continuous and complete isolation from utility disturbances, delivering stable, clean, and uninterrupted power to critical loads.
Advanced DSP Control Technology
High-speed digital signal processing ensures precise control, fast dynamic response, and superior overall system performance.
Unity Output Power Factor (1.0)
Delivers maximum usable power, allowing more load to be supported without oversizing the UPS.
Wide Input Voltage and Frequency Range
Maintains stable operation under unstable grid conditions, reducing battery usage and extending battery life.
Intelligent Battery Management
Includes temperature compensation, automatic battery testing, and optimized charging to extend battery lifespan.
Transformerless High-Efficiency Design
Compact structure with reduced weight and higher efficiency, lowering energy consumption and total cost of ownership.
User-Friendly LCD Display and LED Indicators
Real-time monitoring of system status, alarms, and electrical parameters for easy operation and maintenance.
3 Phase UPS Connection Diagram
The online double-conversion UPS acts as the core of the system. It continuously converts incoming AC power to DC. Then it converts the DC back to clean, regulated AC power. This design fully isolates the load from input power disturbances such as voltage fluctuations, frequency variations, and electrical noise.
An external battery bank or battery cabinet is connected to the UPS to provide uninterrupted backup power during mains failure. The UPS automatically switches to battery mode without interruption, ensuring continuous operation of connected equipment.
The conditioned and regulated output power from the UPS is delivered to various critical loads. This includes servers, data centers, security systems, networking equipment, and industrial devices. This ensures maximum protection and reliability.
UPS System Details
Rear Panel Shown
| 1. SNMP intelligent slot | 2. Cold start function | 3. RS485 communication port |
| 4. RS232 communication port | 5. USB communication port | 6. Emergency power off function connector |
| 7. Share current port(only for parallel model) | 8. Parallel port (only for parallel model) | 9. Line input circuit breaker/switch |
| 10. Manual bypass switch (10kVA – 40kVA optional configuration) | 11. Output switch | 12. Maintenance bypass switch |
| 13. Line connection terminal | 14. Bypass input terminal (10kVA-40kVA optional configuration) | 15. Battery switch |
Rear Panel Connection Terminal
Parallel Wiring Diagram
Dual Input in Parallel Operation
LCD Display
DC Settings Shown
Battery Mode
UPS Specifications
Rated Capacity
-
Power Range: 40kVA/40kW
-
Output Power Factor: 1.0
AC Input
-
Input Phase: Three-phase (3P + N + PE)
-
Nominal Voltage: 380 / 400 / 415 Vac
-
Voltage Range: 110Vac – 300Vac (P-N)
-
Frequency: 50 / 60 Hz (auto-sensing)
-
Power Factor: ≥ 0.99
-
Input THDi: ≤ 3%
AC Output
-
Output Phase: Three-phase (3P + N + PE)
-
Output Voltage: 380 / 400 / 415 Vac
-
Voltage Regulation: ±1%
-
Frequency Accuracy:
-
Utility mode: synchronized to input
-
Battery mode: ±0.1Hz
-
-
Waveform: Pure sine wave
-
Total Harmonic Distortion (THDv):
-
Linear load: ≤ 2%
-
Non-linear load: ≤ 5%
-
Battery
-
Battery Type: VRLA / External battery bank
-
Battery Configuration: 32-40 units(adjustable) for 12v battery
-
Backup Time: Configurable via battery capacity
-
Charging Method: Intelligent multi-stage charging
Parallel Operation
-
Parallel Capability: Up to 4 units
-
Parallel Mode: Capacity expansion or N+1 redundancy
-
Battery System: Shared battery bank supported
Communication & Monitoring
-
Display: LCD + LED indicators
-
Standard Interface: RS232 / RS485 / USB
-
Optional Interface: SNMP, WiFi, GPRS, Dry Contact
-
Monitoring: Local and remote real-time monitoring
Mechanical
-
Design: Transformerless, high-frequency
-
Installation: Tower / Cabinet type
-
Cooling: Intelligent forced air cooling
-
Protection Level: IP20
- Dimension: 250x695x545mm
Applications
-
Data centers and server rooms
-
Medical and healthcare systems
-
Telecom and network equipment
-
Financial and security systems
- Bank ATM
The Articles You may Like
- DSP Based Industrial UPS for Mission-Critical Loads
- Split-phase electric power – Wikipedia
- What is the CT Sensor in Solar Inverter On Off Grid
- Why Does a Lithium Polymer Battery Need a BMS?
- How to Choose 3 Phase Online UPS for Laser Cutting Machine
- Top 5 Reasons to Switch to Lithium Solar Batteries