GT200K PLUS 480v 3 phase uninterruptible power system ups 200kva

GT200K PLUS 480v 3 phase uninterruptible power system ups 200kva

Industrial UPS | 200kVA / 160kW | 3 Phase | 208Vac/220Vac/480Vac | 480Vdc

SKU: GT200K PLUS Category:

Prostar GT200K PLUS 480v 3 phase uninterruptible power system ups 200kva is ideal for data centers, telecommunications, industrial processes, and other mission-critical environments.

Equipped with cutting-edge technology, the uninterruptible power system ups features a double-conversion online design. It can provide a clean and stable output voltage, protecting sensitive equipment from voltage fluctuations, surges, and outages.

The UPS comes with an intuitive LCD display that provides real-time information on system status, battery health, and power metrics. This user-friendly interface simplifies monitoring and management.

GT200K PLUS 480v 3 phase uninterruptible power system ups 200kva

Uninterruptible Power System UPS Features

High Input Power Factor

The uninterruptible power system ups boasts a high input power factor, which reduces the demand on the electrical infrastructure and improves overall energy efficiency. This feature helps in lowering electricity costs and optimizing power usage.

Advanced Online Double Conversion Technology

Ensures seamless power protection with stable output voltage and frequency, regardless of input fluctuations.

Smart Battery Management

The online ups incorporates intelligent battery management technology that optimizes charging and discharging cycles, prolonging battery life and ensuring reliable performance during power outages.

Redundant Power Supply

The UPS unlimited power supply can be configured with redundant power supply options, ensuring that if one power source fails, the other can take over seamlessly, providing an additional layer of reliability.

Scalability and Redundancy

The system supports N+1 or N+X redundancy configurations, allowing multiple units to operate in parallel. This feature enhances reliability and allows for capacity expansion as needed.

Multi-Communication Ports

The UPS supports various communication protocols, including SNMP, RS-232, and RS-485, enabling integration with existing management systems and facilitating remote monitoring and control.

Uninterruptible Power Supply Diagram

GT PLUS UPS 480V 3 Phase Diagram

UPS System Touch LCD Information

Industrial UPS System Inner Components View

Prostar 3 Phase Online UPS Isolation Transformer

UPS Start-up Procedures

1. Confirm Power Supply

Ensure the voltage and frequency from the distribution panel to the UPS terminal are normal.

2. Activate Bypass Mode

  • Turn on the SWBY (Bypass) and SWOUT (Output) switches.
  • The UPS will operate in bypass mode, and the BYIN and BYPASS LED indicators on the panel will illuminate green steadily.

3. Switch to Mains Mode

  • Turn on the SWIN (Main Circuit) switch.
  • After approximately 30 seconds, the UPS will switch to mains inverter mode.
  • The INPUT and INV LED indicators will illuminate green and remain steady.
  • The BYPASS LED indicator will turn off, and the BATTERY LED indicator will begin flashing.

4. Activate Battery Connection

  • After confirming the battery polarity is correctly connected, turn on the Battery Switch.
  • The UPS will automatically detect battery efficiency.
  • The INPUT and INV LEDs will remain green, while the BATTERY LED will turn off.

Important Note

If the touch screen displays “Current status: Phase sequence error” and the BYIN LED is flashing after turning on the SWBY and SWOUT switches, adjust the input phase of the power distribution until the error message clears. Then proceed to turn on the SWIN switch.

 

The Articles You may Like

 

 

ModelGT200K PLUS
Capacity200KVA/160KW
UPS Efficiency>95%
Noise65dB~70dB(Distance 1 Meter)
Dimension(WxDxH mm)2200x908x1650
Weight(Kgs)2500
INPUT
Voltage3 Phases 4 Wires, 208Vac/220Vac/440Vac/480Vac ± 25%
Frequency50Hz/60Hz±5% (Automatically)
Power Factor≥0.95
OUTPUT
Voltage3 Phases 4 Wires, 208Vac/220Vac/440Vac/480Vac ± 1%
Frequency50Hz/60Hz±0.05%(By Battery)
Harmonic DistortionLinear load<3%, Non-linear load<5%
Imbalance VoltageBalance load≤1%, Imbalance load≤3%
Phase Shift AngleBalance load≤1°, Imbalance load≤2°
Transient ResponseOutput at 0~50%~100% ≤5%, response ≤ 10ms
Overload Capacity110%≥300Min, 125%≥10Min, 150%≥1Min
Crest Factor3:1
Wave FormPure sine wave
Transfer Time0ms
BATTERY
TypeSupport VRLA Battery
D.C. Voltage480Vdc
Max. Charging Current0.2AxC10
Charging Time(Standard)12hours
SYSTEM
ProtectionInput over-voltage, under-voltage; output overload, shortcircuit; Inverter over-temperature; Battery under-voltage,over-voltage
IP ProtectionIP20
Parallel ModeN+1,N+X,can be in parallel with different power capacity
Software InterfaceWindows9x,2000,NT,ME,XP,Linux,Novell,Macosx,NT4.0
Meantime Between Failures300,000Hours
ENVIRONMENT
Operating Temperature0℃ to 40℃
Humidity0~95% (non-condensing)
Altitude<1000m (with increase of 100m,it will reduce output of 1%) max. 4000m
Storage Temperature-25℃ to 55℃
MANAGEMENT
Communication InterfaceRS232/RS485
Remote SignalingDry contact (battery low,battery discharging,bypass/fault),EPO
Remote ControlEPO and bypass
SNMP CardPower management from SNMP manager and web browser

 

Prostar 150x40
Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.