MPS150K-50K modular data center online ups 150kva redundancy

Modular UPS | 150kVA/150kW | 3 Phase 4 Wires | +/-192VDC~+/-240VDC | 3 x 50KW Power Module

SKU: MPS150K-50K Category:

Prostar MPS150K-50K modular data center online ups 150kva redundancy is a high‑performance power protection solution. Built on advanced modular architecture, this UPS system delivers exceptional reliability, flexibility, and scalability for medium to large power applications.

Featuring modular power blocks of 50 kVA, the online ups 150kva can be easily configured up to 600 kVA total capacity. It has full N+1 redundancy, ensuring continuous operation. This setup allows zero downtime even during module replacement or maintenance. Its hot‑swappable design allows seamless serviceability without interrupting protected loads, making it ideal for dynamic IT environments.

The system employs online double‑conversion technology to provide clean, stable, and uninterrupted power to sensitive equipment. With high efficiency (>95%), the online ups 150kva offers intelligent load management. It includes advanced communication interfaces to help organizations reduce energy costs. This setup maintains ultimate protection against power disturbances.

 

Prostar MPS150K-50K modular data center online ups 150kva redundancy

 

Modular Online UPS 150kVA Key Features

Modular Design

The system utilizes hot-swappable 50kVA / 50kW power modules. This setup allows flexible configuration up to a full system capacity of 150kVA / 150kW. This is typically achieved with 3 power modules 50kVA/50kW. This modular design enables easy expansion, online maintenance, and future-proof scalability without interrupting power to the load.

N+1 Redundancy

Provides high reliability by allowing multiple UPS units to operate in parallel; if one unit fails, others continue to function without interruption.

Hot-Swappable Power Modules

Facilitates maintenance and upgrades without interrupting the power supply to critical systems.

High Efficiency

Operating in ECO mode can achieve efficiency levels of up to 98.5%, significantly reducing energy costs and heat generation.

LCD Touch Screen

Offers an intuitive user interface for easy monitoring and configuration, along with remote access for convenience and management.

Multiple Protection Functions

Features protections such as Over Voltage Protection (OVP), Over Current Protection (OCP), Over Temperature Protection (OTP), and short circuit protection, ensuring comprehensive safety.

Supports Parallel Operation

Allows for increased capacity and redundancy by connecting multiple UPS units in parallel, suitable for growing data center needs.

Modular Design for Flexible Expansion

MPS150K-50K 3 phase modular data center online ups 150kva redundancy

 

The modular architecture of this modular online UPS 100kVA makes it ideal for projects requiring scalable power solutions. Users do not need to install a large traditional UPS from the beginning. Instead, they can build the system based on real demand, and can expand capacity later.

This modular UPS is designed with 50kVA/50kW power modules, allowing fast installation and flexible upgrades. When a module needs maintenance, it can be replaced quickly. This is possible through a hot-swappable structure, which significantly reduces system downtime. It also helps lower maintenance costs. More details: MPS50K 3 phase modular ups hot-swappable power module 50kW

Output Power Factor 1.0

Prostar 3 Phase Modular UPS System Output Power Factor 1.0

 

This feature maximizes the power delivered to the load, making full use of the UPS capacity. With a power factor of 1.0, the UPS can efficiently support a 150 kVA output, equating to 150 kW of power.

The online UPS 150kVA can deliver its full rated capacity to the load, optimizing the use of available power. A power factor of 1.0 means that users can reduce the size and number of UPS units needed, leading to lower capital expenditure. The higher output capacity can reduce energy losses in the system, enhancing overall operational efficiency.

True Online Double Conversion Technology

Modular online UPS 100kVA adopts online double conversion technology, which continuously converts AC power into DC and then back to AC. This process isolates the load from utility disturbances and provides stable output voltage and frequency.

Compared with line-interactive UPS systems, online UPS provides stronger protection against:

  • Voltage fluctuation

  • Frequency instability

  • Power surges and spikes

  • Electrical noise and harmonic distortion

  • Blackouts and brownouts

With 0ms transfer time, sensitive equipment will not reboot or shut down during power failure.

Technical Specification

Item Specification
UPS Type Modular Online UPS (Double Conversion)
Rated Capacity 150kVA / 150kW
Power Factor 1.0
Power Module 50kVA / 50kW
Phase 3 Phase In / 3 Phase Out
Input Voltage 380/400/415Vac (optional)
Output Voltage 380/400/415Vac
Input Frequency 50/60Hz, 40Hz ~70Hz
Output Frequency 50/60Hz, 46Hz ~ 54Hz or 56Hz ~ 64Hz
Transfer Time 0ms
Battery Voltage ±192VDC ~ ±240VDC
Output Waveform Pure Sine Wave
Efficiency Utility Mode: 95.5%; ECO Mode: 98.5%; Battery Mode: 94.5%
Overload Capacity 60 mins for 110%, 10 mins for 111%-120%,; 1 min for 121%-150%, 200ms for >150%
Display LCD display
Communication RS232 / RS485 / Dry Contact / SNMP (optional)
Parallel Function Supported
Protection Overload, short circuit, over-temperature, battery low voltage, etc.
Application Data center, telecom, hospital, industrial, banking

Battery System & Backup Time

This modular UPS supports an external battery system with battery voltage range ±192VDC to ±240VDC, providing flexible configuration for different backup time requirements.

The UPS typically utilizes Valve-Regulated Lead Acid (VRLA) or Lithium-ion batteries. VRLA offers reliability and cost-effectiveness, while Lithium-ion provides longer life and higher energy density.

Integrated Battery Management Systems (BMS) monitor the health and performance of each battery module, ensuring optimal charging and discharging, thus enhancing battery life.

If you require longer backup time (15minutes, 30 minutes, 1 hour, etc.), we can provide customized battery cabinet and battery pack solutions.

SN Item Power Capacity Backup Time Battery Configuration Battery Type Battery Model
1 Modular UPS 150kVA – 15 mins 150 kVA / 150 kW 15 minutes 1 x 32 × 12V 250Ah Sealed Lead-Acid Battery GP250-12
2 Modular UPS 150kVA – 30 mins 150 kVA / 150 kW 30 minutes 3 x 32 × 12V 200Ah Sealed Lead-Acid Battery GP200-12
3 Modular UPS 150kVA – 60 mins 150 kVA / 150 kW 60 minutes 4 x 32 × 12V 250Ah Sealed Lead-Acid Battery GP250-12

 

Online UPS Details

System Input Information

Prostar 3 Phase Modular UPS System Input Information

Power Module Input Information

Prostar Mars Plus Series Modular UPS Power Module Input Information

 

Applications

The MPS150K-50K UPS is ideal for a variety of applications including:

  • Data Centers: Ensures continuous power for servers, storage, and networking equipment.
  • Telecommunications: Supports critical infrastructure to maintain service without interruptions.
  • Industrial Applications: Provides clean, reliable power for manufacturing and automation processes.

The Articles You may Like

 

Model MPS150K-50K
PHASE 3-phase in/3-phase out
CABINET CAPACITY* 100kVA / 100kW
BATTERY TYPE External Battery
POWER MODULE CAPACITY 50kVA / 50kW
MAX. POWER MODULE NO. 3
SWITCHES NO. 2
INPUT
Nominal Voltage 380VAC/400VAC/415VAC (3P+N+PE)
Voltage Range 110-300VAC@50% load; 176-276VAC@100% load
Nominal Frequency 50/60Hz (Auto Sensing)
Frequency Range 40Hz ~70Hz
Power Factor > 0.99 @ 100% Load, >0.98 @ 50% Load
Harmonic Distortion (THDi) <  4% @ 100% load
OUTPUT
Nominal Voltage 380VAC/400VAC/415VAC (3P+N+PE)
Voltage Regulation (Steady state) ≦ ± 1% Typical (balanced load) ; ≦ ± 2% Typical (unbalanced load)
Voltage Regulation (Transient) ≦ ± 5% Typical
Nominal Frequency 50/60Hz
Frequency Range (Synchronized) 46Hz ~ 54Hz or 56Hz ~ 64Hz
Overload Capability 60 mins for 110%, 10 mins for 111%-120%,; 1 min for 121%-150%, 200ms for >150%
Harmonic Distortion ≦2% THD (Linear Load) ; ≦ 4% THD (Non-linear Load
Efficiency Utility Mode: 95.5%; ECO Mode: 98.5%; Battery Mode: 94.5%
Crest Factor 3:1
Wave Form Pure Sine Wave
BATTERY / CHARGER
Nominal Voltage +/- 192V ~ +/- 240V(Selectable)
Maximum Voltage +/- 240V (12V x 40 pcs)
Minimum Voltage +/- 192V (12V x 32 pcs)
Float Charging Voltage 2.28V / Cell (2.25V ~ 2.33V selectable)
Boost Charging Voltage 2.35V / Cell
Temperature Compensation Yes
Max. Charging Current (Per Power Module) 12A (Adjustable)
PHYSICAL
Cabinet Dimension  (D x W x H) mm 465 x 845 x 1215
Net Weight (Kg) 205
ENVIRONMENT
Operating Temperature 0 ~ 40°C
Relative Humidity 0 ~ 95% non-condensing
Altitude <1000m for Nominal power
IP Class IP 20
MANAGEMENT
Smart RS-232/USB Supports Windows 2000/2003/XP/Vista/2008, Windows 7/8, Linux, Unix, and MAC
Optional SNMP Power management from SNMP manager and web browser
STANDARDS
Safety IEC/EN 62040-1
EMC IEC/EN 62040-2 Category C3
Prostar 150x40
Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.