• MPS200K-50K three phase double conversion modular power supply ups 200 kva

MPS200K-50K double conversion modular power supply ups 200 kva

Modular UPS | 200kVA/200kW | 3 Phase 4 Wires | +/-192VDC~+/-240VDC | 4 x 50KW Power Module

SKU: MPS200K-50K Category:

Prostar MPS200K-50K double conversion modular power supply ups 200 kva designed for mission-critical applications demanding maximum uptime and scalability. With a total capacity of 200 kVA (scalable from 50 kVA modules), this UPS 200kVA delivers pure sine wave output. It utilizes true online double conversion technology. This ensures zero transfer time. It also provides complete isolation from power disturbances like surges, sags, and harmonics.

Hot-swappable 50 kVA power modules allow for easy expansion up to 200 kVA. They also provide N+1 redundancy. This setup minimizes downtime during maintenance or growth.

Prostar MPS200K-50K double conversion modular power supply ups 200 kva

 

Modular UPS 200kVA Key Features

True Online Double-Conversion Topology

It continuously converts incoming AC power to DC. Then, it converts it back to pure AC. This process provides complete isolation from input disturbances, including surges, sags, noise, frequency variations, and harmonics. Output is always stable and clean, regardless of utility power quality.

Scalable Design

Start with the capacity you need today. Scale vertically by inserting additional modules as your power requirements grow. There is no need to replace the entire system.

Hot-Swappable Power Modules

The system utilizes high-density 50 kW (or 50 kVA) intelligent power modules.

High Efficiency

Operating in ECO mode can achieve efficiency levels of up to 98.5%, significantly reducing energy costs and heat generation.

LCD Touch Screen

Offers an intuitive user interface for easy monitoring and configuration, along with remote access for convenience and management.

Intelligent Monitoring

Equipped with a smart monitoring system, the modular ups 200kva provides real-time data on power usage, battery status, and overall system health through a user-friendly interface.

Supports Parallel Operation

Allows for increased capacity and redundancy by connecting multiple UPS units in parallel, suitable for growing data center needs.

Modular Design for Flexible Expansion

MPS200K-50K three phase double conversion modular power supply ups 200 kva

 

The modular UPS 200kVA guarantees uninterrupted power, ensuring the continuous operation of critical equipment and preventing costly downtime. High efficiency leads to reduced operational costs. The modular nature allows users to invest in additional capacity as needed. This can be done without a complete system overhaul.

This modular UPS is designed with 50kVA/50kW power modules, allowing fast installation and flexible upgrades. When a module needs maintenance, it can be replaced quickly. This is possible through a hot-swappable structure, which significantly reduces system downtime. It also helps lower maintenance costs. More details: MPS50K 3 phase modular ups hot-swappable power module 50kW

7-inch LCD Display

The 7-inch touch LCD display is integrated into the modular UPS 200kVA. It is a user-friendly, high-resolution capacitive touchscreen interface. This interface is designed to provide intuitive real-time monitoring. It also allows control and configuration of the entire power system.

Prostar Data Center Modular UPS 7-inch Touch LCD Display

Intuitive Graphical Interface — Modern, icon-based layout with clear menus, real-time dashboards, and color-coded status indicators (green for normal, yellow for warning, red for fault/alarm).

Real-time Monitoring — Displays critical parameters such as:

  • Input/output voltage, current, frequency, and power (kVA/kW)
  • Load percentage and crest factor
  • Battery voltage, charge/discharge current, remaining runtime, and capacity
  • Inverter/bypass/rectifier status
  • Module status (each 50 kW power module)

Alarm & Event Management — Full fault records, operation logs, and predictive warnings with timestamps; supports detailed alarm descriptions and troubleshooting guidance.

Intelligent Battery Management System

The Intelligent Battery Management System (IBMS) in the modular UPS 200kVA is an advanced, microprocessor-controlled feature. It optimizes battery performance and extends service life, also enhances safety and ensures reliable backup power during outages. It actively monitors the external battery bank. The modular ups charges and maintains it. This ensures maximum runtime and minimizes total cost of ownership (TCO).

  • Periodic automatic battery discharge tests (user-scheduled or on-demand) verify actual backup capability without interrupting the load.
  • Equalization charging mode activates as needed to balance cell voltages and correct sulfation in lead-acid batteries.
  • Supports cold-start capability from batteries even if utility power is unavailable.
  • Works with external battery packs (lead-acid VRLA, flooded, or lithium-ion options in supported variants).

  • Integrates seamlessly with the UPS’s DSP-based control system for coordinated operation during transitions (e.g., smooth handover to inverter during blackouts).

Technical Specification

Item Specification
UPS Type Modular Online UPS (Double Conversion)
Rated Capacity 200kVA / 200kW
Power Factor 1.0
Power Module 50kVA / 50kW
Phase 3 Phase In / 3 Phase Out
Input Voltage 380/400/415Vac (optional)
Output Voltage 380/400/415Vac
Input Frequency 50/60Hz, 40Hz ~70Hz
Output Frequency 50/60Hz, 46Hz ~ 54Hz or 56Hz ~ 64Hz
Transfer Time 0ms
Battery Voltage ±192VDC ~ ±240VDC
Output Waveform Pure Sine Wave
Efficiency Utility Mode: 95.5%; ECO Mode: 98.5%; Battery Mode: 94.5%
Overload Capacity 60 mins for 110%, 10 mins for 111%-120%,; 1 min for 121%-150%, 200ms for >150%
Display LCD display
Communication RS232 / RS485 / Dry Contact / SNMP (optional)
Parallel Function Supported
Protection Overload, short circuit, over-temperature, battery low voltage, etc.
Application Data center, telecom, hospital, industrial, banking

 

Modular UPS vs Traditional UPS (Comparison)

Item Modular Online UPS Traditional Online UPS
Capacity Expansion Flexible and scalable Fixed capacity
Maintenance Hot-swappable, fast repair Longer downtime
Reliability Supports N+1 redundancy Limited redundancy
Installation Easier and faster More complex
Total Cost Lower long-term cost Higher long-term cost
Downtime Risk Very low Higher

Online UPS Details

System Input Information

Prostar 3 Phase Modular UPS System Input Information

Power Module Input Information

Prostar Mars Plus Series Modular UPS Power Module Input Information

Typical Applications

  • Medium to large data centers and server rooms
  • Industrial automation and process control systems
  • Financial trading floors and banking infrastructure
  • Telecom base stations and switching centers
  • Healthcare facilities and medical imaging equipment
  • Transportation control systems and critical infrastructure

The Articles You may Like

 

Model MPS200K-50K
PHASE 3-phase in/3-phase out
CABINET CAPACITY* 200kVA / 200kW
BATTERY TYPE External Battery
POWER MODULE CAPACITY 50kVA / 50kW
MAX. POWER MODULE NO. 4
SWITCHES NO. 4
INPUT
Nominal Voltage 380VAC/400VAC/415VAC (3P+N+PE)
Voltage Range 110-300VAC@50% load; 176-276VAC@100% load
Nominal Frequency 50/60Hz (Auto Sensing)
Frequency Range 40Hz ~70Hz
Power Factor > 0.99 @ 100% Load, >0.98 @ 50% Load
Harmonic Distortion (THDi) <  4% @ 100% load
OUTPUT
Nominal Voltage 380VAC/400VAC/415VAC (3P+N+PE)
Voltage Regulation (Steady state) ≦ ± 1% Typical (balanced load) ; ≦ ± 2% Typical (unbalanced load)
Voltage Regulation (Transient) ≦ ± 5% Typical
Nominal Frequency 50/60Hz
Frequency Range (Synchronized) 46Hz ~ 54Hz or 56Hz ~ 64Hz
Overload Capability 60 mins for 110%, 10 mins for 111%-120%,; 1 min for 121%-150%, 200ms for >150%
Harmonic Distortion ≦2% THD (Linear Load) ; ≦ 4% THD (Non-linear Load
Efficiency Utility Mode: 95.5%; ECO Mode: 98.5%; Battery Mode: 94.5%
Crest Factor 3:1
Wave Form Pure Sine Wave
BATTERY / CHARGER
Nominal Voltage +/- 192V ~ +/- 240V(Selectable)
Maximum Voltage +/- 240V (12V x 40 pcs)
Minimum Voltage +/- 192V (12V x 32 pcs)
Float Charging Voltage 2.28V / Cell (2.25V ~ 2.33V selectable)
Boost Charging Voltage 2.35V / Cell
Temperature Compensation Yes
Max. Charging Current (Per Power Module) 12A (Adjustable)
PHYSICAL
Cabinet Dimension  (D x W x H) mm 587 x 845 x 1383
Net Weight (Kg) 288
ENVIRONMENT
Operating Temperature 0 ~ 40°C
Relative Humidity 0 ~ 95% non-condensing
Altitude <1000m for Nominal power
IP Class IP 20
MANAGEMENT
Smart RS-232/USB Supports Windows 2000/2003/XP/Vista/2008, Windows 7/8, Linux, Unix, and MAC
Optional SNMP Power management from SNMP manager and web browser
STANDARDS
Safety IEC/EN 62040-1
EMC IEC/EN 62040-2 Category C3
Prostar 150x40
Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.