Hybrid solar inverter | 5500W | 48VDC | 220Vac/230Vac/240Vac | Feed power into the grid
Prostar PSH-5.5K dc into ac pure sine wave 5500w hybrid solar inverter 48v is a multi-function inverter/charger, combining functions of inverter, MPPT solar charger and battery charger to offer uninterruptible power supply.
PSH-5.5K 5500w hybrid solar inverter 48v can run without battery backup. The Maximum PV array open circuit voltage can reach 450V and MPPT voltage is 150~430V, which can help customers make full use of solar energy.
1.PV connectors 7.Intelligent slot
2.ACoutput connectors 8.DC Switch(option)
3.Battery connectors 9.LCD display panel
4.AC Grid connectors 10.LED indicators
5.RS-232 communication port 11.Operation buttons
6.USB communication port
The UPS and inverter both provides the backup supply to the electrical system. The major difference between the UPS and inverter is that the UPS switches from the main supply to the battery immediately, but the inverter takes much longer.
Keep the cables between your inverter and batteries as short as possible. This will help your batteries perform their best and keep the unit’s signal clean. The cables that come with the inverter are “rated” or good for up to six ft. If you plan on going over six ft., drop down to a larger gauge cable. Please call us if you are still unsure. This is pretty important stuff that should NOT be overlooked. If the cables between your battery and inverter get hot while under heavy load, then you should use heavier cables.
Yes, no problem. If cables need to be run, it is best to keep the unit as close as possible to the batteries. Use extension cords on the output side (Vac output) rather than extending the VDC cables.
Model | PSH5.5K |
PHASE | 1-phase in/1-phase out |
Max. PV INPUT POWER | 6500W |
Rated Output Power | 5500W |
Maximum Charging Power | 2880W |
Dimension, D x W x H (mm) | 110 x 450x 445 |
Net weight (kgs) | 16 |
GRID-TIE OPERATION | |
PV INPUT (DC) | |
Nominal DC Voltage/Max. DC Voltage | 360VDC / 500VDC |
Start-up Voltage/Initial Feeding Voltage | 116VDC / 150VDC |
MPP Voltage Range | 120VDC~450VDC |
Number of MPP Trackers / Maximum Input Current | 2/2x13A |
GRID OUTPUT (AC) | |
Nominal Output Voltage | 208/220/230/240 VAC |
Output Voltage Range | 184 -265 VAC* |
Nominal Output Current | 23.9A* |
Power Factor | >0.99 |
EFFICIENCY | |
Maximum Conversion Efficiency (DC/AC) | 96% |
European Efficiency@Vnominal | 95% |
OFF-GRID OPERATION | |
AC INPUT | |
AC start-up Voltage/Auto Restart Voltage | 120VAC -140VAC / 180VAC |
Acceptable Input Voltage Range | 170VAC – 280VAC |
Max. AC Input Current | 40A |
PV INPUT (DC) | |
Max. DC Voltage | 500VDC |
MPP Voltage Range | 120VDC~450VDC |
Number of MPP Trackers/Max. Input Current | 2/2x13A |
BATTERY Mode Output (AC) | |
Nominal Output Voltage | 202/208/220/230/240VAC |
Output Waveform | Pure Sine Wave |
Efficiency (DC to AC) | 93% |
HYBRID OPERATION | |
PV INPUT (DC) | |
Nominal DC Voltage/Max. DC Voltage | 360VDC / 500VDC |
Start-up Voltage/Initial Feeding Voltage | 116VDC / 150VDC |
MPP Voltage Range | 120VDC~ 450VDC |
Number of MPP Trackers/Max. Input Current | 2/2x13A |
GRID OUTOUT (AC) | |
Nominal Output Voltage | 202/208/220/230/240VAC |
Output Voltage Range | 184-264.5VAC* |
Nominal Output Current | 23.9A* |
AC INPUT | |
AC Start-up Voltage/Auto Restart Voltage | 120VAC – 140VAC /180VAC |
Acceptable Input Voltage Range | 170VAC – 280VAC |
Max. AC Input Current | 40A |
BATTERY MODE OUTPUT (AC) | |
Nominal Output Voltage | 202/208/220/230/240VAC |
Efficiency (DC to AC) | 93% |
BATTERY& CHARGER | |
Nominal DC Voltage | 48 VDC |
Max. Charging Current | 60A |
INTERFACE | |
Communication Port | RS-232/USB |
Intelligent Slot | Optional SNMP, Modbus and AS-400 cards available |
ENVIRONMENT | |
Humidity | 0~90% RH (Non-condensing) |
Operating Temperature | 0°C to 40 °C |
Altitude | 0-1000 m** |