Industrial UPS | 120kVA / 96kW | 3 Phase | 480V Wye Systems | Support VRLA battery or LiFePO4 battery
When a single power interruption can shut down an entire production line, cost thousands per minute in lost output, or corrupt irreplaceable data — the backup power system you choose is not an expense. It is insurance. Prostar ET120K HV is a 120kVA industrial backup UPS engineered specifically for 480V three-phase environments where zero compromise on reliability is the baseline requirement.
Modern industrial facilities are more dependent on stable electricity than ever before. Manufacturing plants, automated production lines, process control systems, industrial robotics, data centers, and critical infrastructure all require continuous, high-quality power to maintain productivity and operational safety.
Even a brief power interruption can result in:
As industries continue to embrace automation and digitalization, power security is no longer simply an electrical concern—it has become a business continuity strategy.
Prostar ET120K HV 120kVA industrial backup UPS is specifically engineered to provide comprehensive power protection for mission-critical applications operating on 480V power systems. Combining advanced online double conversion technology with industrial-grade reliability, it delivers uninterrupted power whenever utility conditions become unstable.
The ET120K HV is a high-performance 120kVA industrial backup UPS designed for medium-to-large industrial facilities requiring continuous power protection.
Built around a true online double conversion UPS architecture, the system continuously converts incoming AC power into DC and then back into clean AC output. This process isolates connected loads from utility disturbances and ensures a seamless transition during power failures.
| Model | ET120K HV |
| Capacity | 120kVA / 96kW |
| Topology | Online Double Conversion |
| Input Voltage | 480V Three Phase, Wye |
| Output Voltage | 480V Three Phase, Wye |
| Application | Industrial Facilities |
| Efficiency | Up to 98% in ECO mode |
| Bypass | Static + maintenance bypass |
| Battery System | External Industrial Battery Bank |
| Monitoring | Intelligent Remote Management |
| Protection Level | Industrial Grade |
This capacity makes it the go-to 120kVA UPS power protection for critical loads across sectors including automotive manufacturing, semiconductor fabs, food processing, and commercial data centers.
Many conventional backup systems only activate when utility power fails. During voltage fluctuations, harmonics, frequency instability, or transient disturbances, sensitive equipment may still be exposed to damaging conditions.
Prostar ET120K HV three phase industrial UPS utilizes true online double conversion technology to eliminate these risks.
The UPS continuously:
As a result, connected equipment receives clean and regulated power at all times.
When a utility outage occurs, the battery system immediately supports the inverter without any transfer delay.
This zero-transfer operation is particularly important for:
These systems often cannot tolerate even milliseconds of power interruption.
Sub-cycle transfer and instantaneous static bypass protect connected loads from voltage sags, spikes, and frequency variations.
Engineered specifically for global industrial voltage standards, ensuring stable 480V output with tight voltage regulation.
Supports an integrated isolation transformer to provide complete electrical separation, neutralizing common-mode noise and ground loops.
Industrial facilities face unique electrical challenges that differ significantly from commercial office environments.
Large motors starting simultaneously can cause temporary voltage drops that disrupt sensitive electronics.
Grid outages can stop entire production lines, resulting in lost output and costly restart procedures.
Variable frequency drives (VFDs) and industrial equipment can introduce harmonics that degrade power quality.
Switching operations and lightning events may generate damaging voltage spikes.
A properly designed industrial power protection system safeguards equipment against all these threats.
The industrial power protection system provides comprehensive protection while supporting large industrial loads with stable, uninterrupted power.
Industrial environments demand more than standard commercial UPS performance.
The ET120K HV 480V industrial UPS system is designed to meet stringent reliability requirements through:
Advanced diagnostics continuously monitor:

Potential issues can be identified before they develop into failures.
Industrial loads often experience temporary overload conditions during startup or process changes.
The UPS is engineered to withstand these conditions while maintaining stable output.
Multiple layers of electrical protection improve operational resilience and reduce the risk of downtime.
Power infrastructure is becoming increasingly connected.
The ET120K HV supports intelligent monitoring functions that enable facility managers to maintain visibility across the entire power protection system.

| ITEM | Description | ITEM | Description |
| 1 | EPO interface | 7 | RS485 / CAN |
| 2 | Dry contact | 8 | NET interface |
| 3 | 250VAC dry contact | 9 | Battery temperature compensation interface |
| 4 | USB port | 10 | USB port |
| 5 | RS485 | 11 | HMI port |
| 6 | RS232 | ||
ET120K HV 120kva industrial backup ups features a comprehensive suite of communication protocols. Equipped with RS232, RS485, Modbus, and optional SNMP slots, plant managers can execute remote monitoring for industrial UPS systems via centralized SCADA or cloud-based dashboards. Real-time telemetry—including load percentages, runtime tracking, and event logs—allows for predictive maintenance, ensuring your facility is never caught off guard.
| Model | ET120K HV |
| Capacity | 120KVA/96KW |
| Topology | Double conversion online |
| Noise | < 65dB from side 1M |
| Dimension(WxDxH mm) | 1290x800x1800 |
| Weight(Kgs) | 986 |
| INPUT | |
| Nominal Voltage | 480Vac, 3P+N+PE |
| Voltage Range | 384 – 576Vac |
| Rated Frequency | 50Hz/60Hz (Automatically) |
| Frequency Range | 40Hz – 70Hz |
| Power Factor | ≥0.95 |
| Input Current Limit | 1.25 x rated input current (settable from 0.1 to 1.25) |
| THDi | < 3% at full load |
| OUTPUT | |
| Output Rated Voltage | 480Vac, 208Vac/220Vac |
| Voltage Regulation | ± 1% |
| Frequency | Mains mode: synchronized with bypass input |
| 50Hz/60Hz±0.01%(By Battery) | |
| THDu | <2% at 100% liner load, <5% at 100% non-liner load |
| Overload Capacity | 105-110%: 60 mins, 110-125%: 10 mins, 125-150%: 1 min, >150%: 200ms |
| Crest Factor | 3:1 |
| Wave Form | Pure sine wave |
| Transfer Time | 0ms |
| ECO MODE | |
| Bypass Output Voltage Range | Upper limit: default 5% (adjustable 5%/10%/15%) |
| Lower limit: default 5% (adjustable 5%/10%/15%) | |
| Bypass Output Frequency Range | Default +/-2Hz (adjustable +/-1Hz, +/-2Hz, +/-3Hz) |
| EFFICIENCY | |
| Efficiency at full load(AC-AC) | > 93% |
| Efficiency at ECO Mode | > 98% |
| BATTERY | |
| Battery Type | Support VRLA battery or LiFePO4 battery option |
| Battery Voltage | 360Vdc default, 336-384VDC |
| Battery Charging Currency | Default 0.2C, adjustable from 0C to 5C depending on battery specification and configuration |
| SYSTEM | |
| Protection | Input over-voltage, under-voltage; output overload, shortcircuit; Inverter over-temperature; Battery under-voltage,over-voltage, fan failure |
| IP Level | IP31 |
| Parallel Number | Up to 8 units |
| Cooling Method | Forced air cooling (fans) |
| Display | 7-inch color LCD touch screen |
| Audible Alarm | Audible and visual alarms prioritized by fault severity |
| ENVIRONMENT | |
| Operating Temperature | 0℃ to 40℃ |
| Storage Temperature | -20℃ to 55℃ |
| Humidity | 0~95% (non-condensing) |
| Altitude | <1000m (with increase of 100m,it will reduce output of 1%) |
| COMMUNICATION | |
| Communication Interface | RS232,RS485, USB, Dry contact, EPO (option: battery temperature compensation) |
| Intelligent Slot | Support SNMP card / web interface for advanced remote monitoring, management, and network integration |
Prevents tool breakage, scrap material, and recalibration downtime caused by momentary voltage sags.
Critical monitoring and control systems must remain operational during power disturbances.
The UPS protects:
Power plants require reliable backup for:
Airports, rail systems, and logistics centers depend on uninterrupted power for operational continuity.