• PET1103B security online ups 3kva battery backup power supply for pc
  • PET1103 pf1 best uninterruptible power supply 3000va ups for computer

PET1103B security online ups 3kva battery backup power supply for pc

Double Conversion UPS | 3000VA / 3000W | 72Vdc | 208V/220V/230V/240V | Built-in 6 x12V7AH UPS battery

SKU: PET1103B Category:

Prostar PET1103B security online ups 3kva battery backup power supply for pc offers compact single phase UPS power protection for commercial and technical facilities.

PET1103B online ups 3kva is up to seven percent more efficient than other UPSs in its class, helping to keep your operating costs down.

POWERONE online double conversion ups has been designed as combined advanced IGBT technology with PWM technology.

This online UPS 3KVA provides continuous and clean power to your computer, server, or network equipment, even during power outages or fluctuations in the input voltage. With its true online double-conversion technology, the UPS filters out any noise or voltage spikes, ensuring that your devices receive a stable and consistent power supply.

PET single phase pure sine wave double conversion online ups 1KVA-3KVA

Online UPS 3KVA Features

  • True double conversion
  • Microprocessor control optimizes reliability
  • DSP technology guarantees high performance
  • Pure sine wave output
  • Input power factor correction
  • Output power factor 1
  • Extremely wide input voltage window of 110 VAC to 300 VAC
  • 50Hz/60Hz frequency converter mode
  • ECO and frequency operating voltage possibilities
  • Graphic LCD display with interactive multilingual user interface
  • Adjustable charging current/charging mode via LCD panel
  • Built-in 6PCS 12V 7AH lead acid battery
  • Programmable output voltage
  • Cold start by battery without grid Input
  • Generator compatible
  • Extension slot for SNMP, potential-free contacts, remote panel

Online UPS Highlight

PET single phase pure sine wave double conversion online ups 1KVA-3KVA PF1

PET single phase online UPS 1KVA-10KVA multiple protection

Best Online UPS Details

PET1103B security online ups 3kva battery backup power supply for pc

PET1103 pf1 best uninterruptible power supply 3000va ups for computer

HF Online UPS 3KVA Rear

PET1103B Single Phase HF Online UPS 3000VA Rear

Single Phase HF Online UPS Rear Description

 

Online Double Conversion UPS FAQ

  1. What is the difference between a battery and a UPS?

    A battery is a device that stores energy, a UPS detects when there is no longer any power coming from the mains and switches over to the UPS batteries.

  2. Is it possible to monitor the UPS through my computer?

    Yes, it is possible to monitor the UPS through your computer via the RS232 or USB ports which are a standard built-in feature in the new-age UPS power backup systems. It is also possible to monitor the UPS over a network with the help of an optional SNMP/ Network card. UPS software is available for free download if you wish to access the information online. Automatic SMS/ Email alerts can be set for intimation of any status change in the functioning of the UPS.

  3. Can I use a UPS for 5-6 hours?

    If the power requirement is low and the UPS is overrated, possibly, but normally running a UPS for this long requires so many UPS batteries it becomes unfeasible both financial and physically. It would be best to run a standby generator alongside your UPS to achieve this.

The Articles You may Like

    Request Product Price


    * Required

    MODEL PET1103B
    CAPACITY 3000VA / 3000W
    Battery Voltage 72VDC
    Size, D X W X H (mm) 445 X 190 X 330
    Net Weight (kgs) 22
    INPUT
    Norminal Voltage 208/220/230/240VAC
    Input Voltage Range 110-300VAC
    Frequency Range 50Hz:44Hz~56Hz or 60Hz:54Hz~66Hz
    Phase Single Phase, L+N+PE
    Power Factor ≧ 0.99 @ nominal voltage (input voltage)
    Harmonic Distortion ≤4% (Linear Load), ≤5% (Non-linear Load)
    OUTPUT
    Output voltage 208/220/230/240VAC
    AC Voltage Regulation ± 1% (Batt. Mode)
    Frequency Range(Line Mode) Synchronized range
    Frequency Range (Batt. Mode) 50 Hz or 60Hz ± 0.1%
    Overload Capacity AC Mode:                                                                       Battery Mode:
    30mins @102%-110% load                                             1min @102%-110% load
    10mins @110%-130% load                                             10sec @110%-130% load
    30sec @130%-150% load                                                3sec @110%-130% load
    200ms @>150% load                                                      200ms @>150% load
    Current Crest Ratio 3:1
    Harmonic Distortion ≦3% THD (Linear Load);≦5% THD (Non-linear Load)
    Transfer Time AC Mode to Battery Mode 0ms
    Inverter to Bypass 4ms
    Waveform (Batt. Mode) Pure Sine Wave
    EFFICIENCY
    AC Mode 95.5%
    Battery Mode 89.5%
    BATTERY
    Battery Type Sealed Maintenance-free
    Battery Numbers 6 PCS x 12V7AH
    Charging Current 1A(Default),1A-4A adjustable
    Charging Voltage 82.2VDC ± 1%
    Charging Mode 2-stage or 3-stage
    INDICATORS
    LCD Panel Load level, Battery level, AC mode, Battery mode, Bypass mode,and Fault condictions
    ENVIRONMENT
    Ambient temperature 0- 40°C
    Operation Humidity 20%-95% (non-condensing)
    Storage temperature -15~60℃ (no battery inside)
    Altitude <1000m ( the height above 1000m should be reduced to a maximum of 4000m.)
    Noise Level Less than 50dBA @ 1 Meter
    COMMUNICATION
    Communication Inteface Standard: RS232, USB; Option: Dry contact, EPO
    Smart Slot Optional SNMP Card