ET80K HV 480v 80kva industrial ups for manufacturing plants

Industrial UPS | 80kVA / 64kW | 3 Phase | 480V Wye Systems | Support VRLA battery or LiFePO4 battery

SKU: ET80K HV Category:

Modern manufacturing plants depend heavily on stable electrical power. CNC machines, PLC systems, robotic production lines, industrial automation equipment, and precision testing instruments are highly sensitive to voltage fluctuations, frequency instability, and sudden power outages.

Even a short interruption lasting less than one second can result in:

  • Production downtime
  • Damaged raw materials
  • PLC communication failure
  • Motor control errors
  • Data loss
  • Equipment shutdown
  • Significant financial losses

For factories operating 24/7, power continuity is no longer optional. A high-performance 80kVA industrial UPS system becomes a critical part of the plant power infrastructure.

Prostar ET80K HV 80kVA Industrial UPS 480V is designed specifically for harsh industrial environments where reliability, load adaptability, and electrical isolation are essential.

What is the ET80K HV 80kVA Industrial UPS?

Prostar ET80K HV is a 3-phase 480V online double-conversion UPS designed for industrial manufacturing plants requiring stable power for heavy electrical loads. It is designed for 480V industrial manufacturing environments where power interruptions can cause production line downtime.

Common Power Problems in Manufacturing Plants

Industrial facilities often face more severe electrical conditions than commercial buildings.

Typical power issues include:

Voltage Sags and Surges

Large motors, compressors, and welding machines can create sudden voltage drops or spikes.

Harmonic Distortion

Variable frequency drives (VFDs) and nonlinear loads generate harmonics that affect sensitive equipment.

Frequent Power Interruptions

Unstable utility grids or generator switching can interrupt production processes.

High Inrush Current

Industrial machinery often creates heavy startup currents that overload ordinary UPS systems.

Electrical Noise

EMI and transient interference may affect control systems and industrial communication networks.

A conventional office UPS is usually unable to handle these conditions reliably.

Prostar ET80K HV 480v 80kva industrial ups for manufacturing plants

Why Commercial UPS Systems Fail in Industrial Applications

Many standard UPS systems are designed primarily for office IT environments rather than industrial manufacturing.

Typical weaknesses include:

  • Poor overload capability
  • Weak motor load adaptability
  • No galvanic isolation
  • Limited tolerance for harsh environments
  • Insufficient short-circuit protection
  • Reduced reliability under high ambient temperatures

Manufacturing plants require a 80kVA industrial UPS engineered specifically for industrial electrical conditions.

ET80K HV 80kVA Industrial UPS Solution

The ET80K HV 480V Industrial UPS is a true online double-conversion UPS developed for mission-critical industrial applications.

It delivers clean and uninterrupted power for manufacturing facilities operating under demanding electrical conditions.

What happens

Plant generator engages. Mechanical governor takes 3-5 seconds to stabilize frequency between 58-62 Hz. Commercial UPS sees ±3 Hz deviation, declares utility “unacceptable,” and runs on battery until depleted.

ET80K HV 80kVA Industrial UPS Solution

Programmable frequency tolerance up to ±10 Hz plus a dedicated “Generator Mode” that widens acceptance windows while maintaining full double-conversion protection. No battery drain during generator ramp-up.

Built-in Galvanic Isolation Transformer

One of the most important advantages of the ET80K HV industrial UPS is its built-in galvanic isolation transformer. This feature provides complete electrical isolation between the utility input and the critical load.

 

Prostar ET HV 480V UPS system with isolation transformer for heavy industry backup

Why Isolation Matters

Industrial environments commonly experience:

  • Ground loop problems
  • Electrical noise
  • Common mode interference
  • Harmonic disturbances

Benefits

  • Protection against electrical noise and transient surges
  • Improved load safety in industrial environments
  • Reduced common-mode interference
  • Enhanced compatibility with sensitive manufacturing equipment
  • Better grounding performance for industrial automation systems

The galvanic isolation design is especially valuable for:

  • CNC machinery
  • PLC control systems
  • Robotics production lines
  • Industrial automation equipment
  • Semiconductor manufacturing systems
  • Oil and gas facilities
  • Chemical processing plants

True Online Double Conversion Technology

The ET80K HV uses online double-conversion architecture to continuously regulate power quality.

The UPS converts incoming AC power into DC and then reconstructs a completely stable AC output.

This architecture eliminates:

  • Voltage fluctuation
  • Frequency instability
  • Transfer switching delay
  • Utility disturbances

As a result, sensitive industrial equipment always receives stable and pure sine wave power.

Advantages include:

  • Zero transfer time
  • Stable output voltage and frequency
  • Complete isolation from utility disturbances
  • Harmonic filtering
  • Protection against:
    • Voltage sag
    • Voltage surge
    • Frequency instability
    • Brownouts
    • Blackouts
    • Electrical noise

Cold Start Capability

The ET80K HV 80kVA industrial UPS supports Cold Start Capability, allowing the UPS to start directly from battery power without utility input.

This function is extremely important during:

  • Complete grid failures
  • Emergency maintenance
  • Remote industrial site operations
  • Critical startup procedures
  • Black start industrial applications

With cold start functionality, manufacturing plants can safely initialize critical systems even when utility power is unavailable.

Rugged Industrial Design

Industrial environments can be extremely challenging for electronic equipment.

The ET80K HV 80kVA industrial ups is designed with a rugged industrial structure suitable for:

  • Dusty environments
  • High-temperature conditions
  • Heavy electrical interference
  • Continuous operation environments

Its robust design improves long-term operational reliability and reduces maintenance risk.

Applications

Application Fit Level Why?
Welding robots (servo-driven) Excellent Handles regenerative energy from deceleration.
Conveyor systems (multiple motors) Excellent 150% overload for 10min supports staggered starts.
CNC machining centers Good Clean 480V output eliminates spindle controller faults.
HVAC for cleanrooms Moderate Use with soft-starters; not direct-DOL starters >50HP.
Lighting / office loads Overkill Use a cheaper 120/208V UPS.

 

Parameters

Model ET80K HV
UPS Capacity 80kVA / 64kW
Input Info 480V AC @ 50Hz/60Hz
Output Info 480V AC @ 50Hz/60Hz
UPS Topology Online Double Conversion
Transformer Built-in Galvanic Isolation Transformer
Startup Function Cold Start Supported
Communication RS232 / RS485 / Modbus / SNMP / USB
Overload Capacity 110% (60 min), 125% (10 min), 150% (1 min)
Battery Type VRLA / Lithium-ion
Application Environment Industrial Manufacturing Plants
Protection Level Industrial Grade

LCD Display Show

Prostar 3 Phase Industrial Online UPS with transformer Online Mode

Prostar 3 Phase Industrial Online UPS with transformer Battery Mode

 

Real-Time High Voltage Lithium Battery Monitoring

For manufacturing plants using lithium battery energy storage systems, battery visibility is just as important as UPS reliability.

The ET80K HV 80kVA industrial UPS supports communication with high-voltage lithium battery systems through CAN Bus or RS485 protocols. By exchanging data with the BMS, the UPS can display real-time battery information directly on its LCD touchscreen.

This enables maintenance personnel to monitor battery health, identify abnormal cells, and prevent unexpected downtime.

Battery Group Overview Screen

Prostar 3 Phase Online UPS Battery Pack Overview Screen

The battery group information page provides a complete overview of the battery system.

Key parameters include:

Parameter Description
Total Voltage Total battery pack voltage
Total Current Charging or discharging current
SOC State of Charge
SOH State of Health
Battery Status Charge, Discharge, Standby
Fault Codes BMS alarm and protection information

For example:

Total Voltage: 512V
SOC: 82%
SOH: 98%
Status: Discharging

These values help operators quickly evaluate battery condition and remaining backup runtime.

Individual Cell Monitoring Screen

The Individual Cell Information page displays detailed voltage and temperature data for each battery cell.

Prostar 3 Phase Online UPS Individual Cell Monitoring Screen

Prostar 3 phase online UPS can display:

  • Cell Voltage (mV)
  • Cell Temperature (°C)
  • Maximum Cell Voltage
  • Minimum Cell Voltage
  • Voltage Difference Between Cells
  • Highest Temperature
  • Lowest Temperature

This feature helps maintenance teams detect:

  • Cell imbalance
  • Over-voltage conditions
  • Under-voltage conditions
  • Over-temperature events
  • Battery aging

before they become critical failures.

Why Cell-Level Monitoring Matters

In large manufacturing plants, a high-voltage lithium battery bank may contain:

  • 96 cells
  • 128 cells
  • 160 cells
  • 192 cells

Even a single abnormal cell can reduce the performance of the entire battery system.

By continuously monitoring individual cell data, the ET80K HV UPS helps improve:

  • Battery safety
  • System reliability
  • Predictive maintenance
  • Battery service life
  • Production continuity

FAQ

What makes an industrial UPS different from a standard UPS?

Industrial UPS systems are designed for harsh environments with stronger electrical protection, higher overload capability, and improved reliability for industrial equipment.

Why is galvanic isolation important in manufacturing plants?

Galvanic isolation protects sensitive industrial equipment from electrical noise, ground loops, and transient disturbances commonly found in industrial environments.

Can Prostar ET80K HV online UPS support heavy industrial loads?

Yes. The ET80K HV is designed for demanding industrial applications including motor-driven equipment, automation systems, and manufacturing production lines.

What is the benefit of cold start capability?

Cold start allows the UPS to start directly from batteries when utility power is unavailable, enabling emergency operation of critical equipment.

Can the ET80K HV UPS Monitor Individual Lithium Battery Cells?

Yes. When connected to a compatible lithium battery BMS via CAN Bus or RS485 communication, this allows operators to perform real-time battery diagnostics and preventive maintenance.

Can the ET80K HV 80kVA industrial UPS run on a generator?

Yes. This UPS for manufacturing plant includes a programmable generator mode with ±8 Hz frequency tolerance, preventing unnecessary battery drain.

What battery voltage is required for this factory power protection system?

384VDC for lead-acid batteries, or 358.4VDC for high-voltage lithium batteries.

Is this 480V three phase UPS system suitable for CNC machines?

Yes. With <2% at 100% liner load, <5% at 100% non-liner load, it eliminates spindle controller faults and position errors.

What is the transfer time of this 80kVA industrial UPS?

Zero milliseconds (true online double-conversion).

Can multiple ET80K HV units run in parallel as a factory power protection system?

Yes. Up to 8 units can be paralleled for N+1 redundancy or capacity expansion.

What is the overload capacity of this 480V three phase UPS system?

110% for 60 minutes, 125% for 10 minutes, 150% for 1 minute — essential for motor starting in any UPS for manufacturing plant.

 

The Articles You may Like

 

 

Model ET80K HV
Capacity 80KVA/64KW
Topology Double conversion online
Noise < 65dB from side 1M
Dimension(WxDxH mm) 1010x700x1600
Weight(Kgs) 735
INPUT
Nominal Voltage 480Vac, 3P+N+PE
Voltage Range 384 – 576Vac
Rated Frequency 50Hz/60Hz (Automatically)
Frequency Range 40Hz – 70Hz
Power Factor ≥0.95
Input Current Limit 1.25 x rated input current (settable from 0.1 to 1.25)
THDi < 3% at full load
OUTPUT
Output Rated Voltage 480Vac,  208Vac/220Vac
Voltage Regulation ± 1%
Frequency Mains mode: synchronized with bypass input
50Hz/60Hz±0.01%(By Battery)
THDu <2% at 100% liner load, <5% at 100% non-liner load
Overload Capacity 105-110%: 60 mins, 110-125%: 10 mins, 125-150%: 1 min, >150%: 200ms
Crest Factor 3:1
Wave Form Pure sine wave
Transfer Time 0ms
ECO MODE
Bypass Output Voltage Range Upper limit: default 5% (adjustable 5%/10%/15%)
Lower limit: default 5% (adjustable 5%/10%/15%)
Bypass Output Frequency Range Default +/-2Hz (adjustable +/-1Hz, +/-2Hz, +/-3Hz)
EFFICIENCY
Efficiency at full load(AC-AC) > 93%
Efficiency at ECO Mode > 98%
BATTERY
Battery Type Support VRLA battery or LiFePO4 battery option
Battery Voltage 360Vdc default, 336-384VDC
Battery Charging Currency Default 0.2C, adjustable from 0C to 5C depending on battery specification and configuration
SYSTEM
Protection Input over-voltage, under-voltage; output overload, shortcircuit; Inverter over-temperature; Battery under-voltage,over-voltage, fan failure
IP Level IP31
Parallel Number Up to 8 units
Cooling Method Forced air cooling (fans)
Display 7-inch color LCD touch screen
Audible Alarm Audible and visual alarms prioritized by fault severity
ENVIRONMENT
Operating Temperature 0℃ to 40℃
Storage Temperature -20℃ to 55℃
Humidity 0~95% (non-condensing)
Altitude <1000m (with increase of 100m,it will reduce output of 1%)
COMMUNICATION
Communication Interface RS232,RS485, USB, Dry contact, EPO (option: battery temperature compensation)
Intelligent Slot Support SNMP card / web interface for advanced remote monitoring, management, and network integration