Modular UPS | 500kVA/500kW | 4 Breakers | +/-192VDC~+/-240VDC | 10 x 50KW Power Module
Prostar MPS500K-50K three phase modular data center ups online 500kva designed specifically for mission-critical data center environments. This 500kVA online double-conversion modular data center UPS is engineered for scalability. It offers redundancy and maximum uptime. The UPS provides clean, reliable, and efficient power protection for servers, storage equipment, and networking infrastructure.

Scalability
The system frame supports up to 500kVA and contains individual power modules (typically 50kW/kVA per module). Users can start with a smaller configuration (e.g., 50kVA, 100kVA) and add modules as load requirements increase.
Hot-Swap Capability
Power modules, static switches, and control units are designed for hot-swap replacement. This enables “Zero Downtime” maintenance. Technicians can replace faulty modules in seconds without transferring the critical load to bypass or shutting down IT equipment.
High Efficiency (Online Mode)
Peak Efficiency: Up to 95.5% in double-conversion mode.
The high efficiency reduces heat dissipation. It lowers cooling requirements and operational costs. As a result, there is a lower TCO (Total Cost of Ownership) and PUE (Power Usage Effectiveness) for your facility.
The modular architecture allows for configurable redundancy. Users can configure the system for N+1 or N+X redundancy. This setup ensures that if one module fails, the remaining modules instantly take over the full load. There is no interruption, guaranteeing 100% load availability.
LCD Touch Screen
Offers an intuitive user interface for easy monitoring and configuration, along with remote access for convenience and management.
Remote Management
The system is equipped with multiple communication slots for SNMP, Modbus, and TCP/IP protocols. This allows seamless integration with data center infrastructure management (DCIM) platforms and remote monitoring tools.
Extended Battery Life
Features intelligent battery management, including temperature-compensated charging and automatic battery testing to prolong battery lifespan.

The system is constructed using hot-swappable 50kVA power modules. A standard cabinet can house up to 10 modules to achieve the full 500kVA capacity.
This modular UPS features 50kVA/50kW power modules, allowing fast installation and flexible upgrades. When a module needs maintenance, you can replace it quickly. This is possible through a hot-swappable structure, which significantly reduces system downtime. It also helps lower maintenance costs. More details: MPS50K 3 phase modular ups hot-swappable power module 50kW
The MPS500K-50K adopts a 50kVA / 50kW power module design. This design enables flexible system configuration. Capacities range from lower levels up to 600kVA within a single cabinet. Additional cabinets can be paralleled for even higher power demands.
Power module: 50kVA / 50kW
System capacity: Up to 600kVA per cabinet
Parallel expansion capability for large power systems
Hot-swappable power modules without downtime

This modular architecture allows data center operators to invest according to current needs. It maintains the flexibility to expand as business grows.
Redundant design and hot-swappable components allow maintenance without interrupting the protected load, significantly improving system availability.
The 500kVA modular data center UPS system integrates a 7-inch touch LCD display. It is a user-friendly, high-resolution capacitive touchscreen interface. This interface is designed to provide intuitive real-time monitoring. It also allows control and configuration of the entire power system.

Intuitive Graphical Interface — Modern, icon-based layout with clear menus, real-time dashboards, and color-coded status indicators (green for normal, yellow for warning, red for fault/alarm).
Real-time Monitoring — Displays critical parameters such as:
Alarm & Event Management — Full fault records, operation logs, and predictive warnings with timestamps; supports detailed alarm descriptions and troubleshooting guidance.
| Item | Specification |
|---|---|
| UPS Type | Modular Online UPS (Double Conversion) |
| Rated Capacity | 500kVA / 500kW |
| Power Factor | 1.0 |
| Power Module | 50kVA / 50kW |
| Phase | 3 Phase In / 3 Phase Out |
| Input Voltage | 380/400/415Vac (optional) |
| Output Voltage | 380/400/415Vac |
| Input Frequency | 50/60Hz, 40Hz ~70Hz |
| Output Frequency | 50/60Hz, 46Hz ~ 54Hz or 56Hz ~ 64Hz |
| Transfer Time | 0ms |
| Battery Voltage | ±192VDC ~ ±240VDC |
| Output Waveform | Pure Sine Wave |
| Efficiency | Utility Mode: 95.5%; ECO Mode: 98.5%; Battery Mode: 94.5% |
| Overload Capacity | 60 mins for 110%, 10 mins for 111%-120%,; 1 min for 121%-150%, 200ms for >150% |
| Display | LCD display |
| Communication | RS232 / RS485 / Dry Contact / SNMP (optional) |
| Parallel Function | Supported |
| Protection | Overload, short circuit, over-temperature, battery low voltage, etc. |
| Application | Data center, telecom, hospital, industrial, banking |



| Model | MPS500K-50K |
| PHASE | 3-phase in/3-phase out |
| CABINET CAPACITY* | 500kVA / 500kW |
| BATTERY TYPE | External Battery |
| POWER MODULE CAPACITY | 50kVA / 50kW |
| MAX. POWER MODULE NO. | 12 |
| SWITCHES NO. | 4 |
| INPUT | |
| Nominal Voltage | 380VAC/400VAC/415VAC (3P+N+PE) |
| Voltage Range | 110-300VAC@50% load; 176-276VAC@100% load |
| Nominal Frequency | 50/60Hz (Auto Sensing) |
| Frequency Range | 40Hz ~70Hz |
| Power Factor | > 0.99 @ 100% Load, >0.98 @ 50% Load |
| Harmonic Distortion (THDi) | < 4% @ 100% load |
| OUTPUT | |
| Nominal Voltage | 380VAC/400VAC/415VAC (3P+N+PE) |
| Voltage Regulation (Steady state) | ≦ ± 1% Typical (balanced load) ; ≦ ± 2% Typical (unbalanced load) |
| Voltage Regulation (Transient) | ≦ ± 5% Typical |
| Nominal Frequency | 50/60Hz |
| Frequency Range (Synchronized) | 46Hz ~ 54Hz or 56Hz ~ 64Hz |
| Overload Capability | 60 mins for 110%, 10 mins for 111%-120%,; 1 min for 121%-150%, 200ms for >150% |
| Harmonic Distortion | ≦2% THD (Linear Load) ; ≦ 4% THD (Non-linear Load |
| Efficiency | Utility Mode: 95.5%; ECO Mode: 98.5%; Battery Mode: 94.5% |
| Crest Factor | 3:1 |
| Wave Form | Pure Sine Wave |
| BATTERY / CHARGER | |
| Nominal Voltage | +/- 192V ~ +/- 240V(Selectable) |
| Maximum Voltage | +/- 240V (12V x 40 pcs) |
| Minimum Voltage | +/- 192V (12V x 32 pcs) |
| Float Charging Voltage | 2.28V / Cell (2.25V ~ 2.33V selectable) |
| Boost Charging Voltage | 2.35V / Cell |
| Temperature Compensation | Yes |
| Max. Charging Current (Per Power Module) | 12A (Adjustable) |
| PHYSICAL | |
| Cabinet Dimension (D x W x H) mm | 1200 x 850 x 2000 |
| Net Weight (Kg) | 620 |
| ENVIRONMENT | |
| Operating Temperature | 0 ~ 40°C |
| Relative Humidity | 0 ~ 95% non-condensing |
| Altitude | <1000m for Nominal power |
| IP Class | IP 20 |
| MANAGEMENT | |
| Smart RS-232/USB | Supports Windows 2000/2003/XP/Vista/2008, Windows 7/8, Linux, Unix, and MAC |
| Optional SNMP | Power management from SNMP manager and web browser |
| STANDARDS | |
| Safety | IEC/EN 62040-1 |
| EMC | IEC/EN 62040-2 Category C3 |