Modular UPS Power Modular | 50KVA / 50KW | 3 Phases 4 Wires | +/-192VDC ~ +/-240VDC
The hot-swappable power module 50kW offers a robust solution. It meets the increasing demands for power reliability. It also enhances efficiency in modern infrastructures. This advanced UPS is designed to empower your business operations, ensuring that you remain resilient against power interruptions.
Power Range: 50kVA/50kW
Output Power Factor: 1.0
Input Phase: Three-phase (3P + N + PE)
Nominal Voltage: 380 / 400 / 415 Vac
Voltage Range: 110Vac – 300Vac (P-N)
Frequency: 50 / 60 Hz (auto-sensing)
Power Factor: ≥ 0.99
Input THDi: ≤ 4%
Output Phase: Three-phase (3P + N + PE)
Output Voltage: 380 / 400 / 415 Vac
Voltage Regulation: ±1%
Frequency Accuracy:
Utility mode: synchronized to input
Battery mode: 50Hz / 60Hz ±0.1Hz
Waveform: Pure sine wave
Total Harmonic Distortion (THDv):
Linear load: ≤ 2%
Non-linear load: ≤ 4%
Battery Type: VRLA / External battery bank
Battery Configuration: 32-40 units(adjustable) for 12v battery
Backup Time: Configurable via battery capacity
Charging Method: Intelligent multi-stage charging
Parallel Capability: Up to 24 units
Parallel Mode: Capacity expansion or N+1 redundancy
Battery System: Shared battery bank supported
Display: LCD + LED indicators
Standard Interface: RS232 / RS485 / USB
Optional Interface: SNMP, WiFi, GPRS, Dry Contact
Monitoring: Local and remote real-time monitoring
Design: Transformerless, high-frequency
Installation: Tower / Cabinet type
Cooling: Intelligent forced air cooling
Protection Level: IP20
| Cabinet Model | MPS50K |
| Maximum Capacity | 50KVA / 50KW |
| Phase | 3-phase in / 3-phase out |
| Battery Voltage | 240V Default, 192V/240V Selectable |
| Size, D X W X H (mm) | 650x438x130 [3U] |
| Weight (Kgs) | 32 |
| INPUT | |
| Input Voltage | 380VAC/400VAC/415VAC (3Ph+N) |
| Voltage Range | 305~477VAC at 100% Load; 208~304VAC at <70% Load |
| Nominal Frequency | 50/60Hz(Auto Sensing) |
| Frequency Range | 40Hz~70Hz |
| Power Factor | >0.99 @ 100% Load, >0.98 @ 50% Load |
| Harmonic Distortion (THDi) | < 3% @ 100% Load |
| OUTPUT | |
| Nominal Voltage | 380VAC/400VAC/415VAC (3Ph+N) |
| Voltage Regulation(Steady state) | ≦±1%Typical(Balanced Load);≦±2% Typical (Unbalanced Load) |
| Voltage Regulation(Transient) | ≦±5% Typical |
| Nominal Frequency | 50/60Hz |
| Frequency Range(Synchronized) | 46Hz~54Hz or 56Hz~64Hz |
| Power Factor | 1 (kVA=kW) |
| Overload Capability | 1 hour for 110%,10 min for 120%,1 min for 150%,200ms for >150% |
| Harmonic Distortion | ≦1.5% THD(Linear Load);≦4% THD( Non-linear Load ) |
| Efficiency | Up to 94.5% |
| BATTERY/CHARGER | |
| Nominal Voltage | +/- 216V (12V x 36Pcs) |
| Maximum Voltage | +/- 240V (12V x 40Pcs) |
| Minimum Voltage | +/- 192V (12V x 32Pcs) |
| Float Charging Voltage | 2.25V/Cell |
| Boost Charging Voltage | 2.35V/Cell |
| Temperature Compensation | Yes |
| Maximum Charging Current | 12A for each power module (User adjustable) |
| STANDARDS | |
| Safety | IEC/EN 60950-1; IEC/EN 62040-1 |
| EMC | IEC/EN 62040-2 Category C3 |
| ENVIRONMENT | |
| Operation Temperature | 0~40°C |
| Relative Humidity | 0~95% Non-condensing |
| Altitude | <1000m for Nominal power |
| IP Class | IP20 |