PET1103+Li 3kVA lithium UPS 48V online double conversion for pc

PET1103+Li 3kVA lithium UPS 48V online double conversion for pc

Lithium Battery UPS | 3000VA/3000W | 48VDC | 1-30A Charging | BMS

SKU: PET1103+Li Category:

Prostar PET1103+Li is a 3kVA lithium UPS for professional PC systems, workstations, network devices, edge computing equipment, and small IT infrastructures that require stable and uninterrupted power protection. This 3kVA lithium UPS uses 48V LiFePO4 lithium battery technology and online double conversion topology. It outputs pure sine wave, transfers at 0 ms, achieves 95% efficiency in double-conversion mode and 98% in ECO mode, and supports 6,000+ cycles at 80% DoD versus 300–500 cycles for lead-acid systems. This lithium battery UPS suits users who need long runtime, lower maintenance, and intelligent power management.

Critical Power Challenge in Modern Computing Environments

Modern high-performance PCs, multi-GPU AI development workstations, and rack servers use Switch-Mode Power Supplies (SMPS) with Active Power Factor Correction (PFC). Line-interactive UPS units and lead-acid backups fail in these environments due to three systemic vulnerabilities:

Transfer Time Latencies and Waveform Distortion

Line-interactive UPS units introduce a 4ms to 20ms transfer lag during power dips or blackouts. Active PFC PC power supplies trigger an instantaneous low-voltage shutdown within 4ms–8ms. This causes unrecorded data loss, corruption of machine-learning models, or hardware strain.

Rapid Degradation of Lead-Acid (VRLA) Batteries

Valve-Regulated Lead-Acid (VRLA) batteries have 300 to 500 cycles or 2–3 years of service life. In high-density PC environments with ambient thermal load, VRLA cells undergo thermal runaway and capacity degradation. This requires replacements every 2–3 years.

Voltage Fluctuations, Harmonics, and Grid Noise

Commercial electrical grids produce micro-sags, transient surges, frequency drifts, and total harmonic distortion (THD). Unconditioned power erodes semiconductor components inside GPUs and CPUs over time and reduces system longevity.

PET1103+Li double conversion 48V 3kVA lithium UPS for computer

 

PET1103+Li 3kVA Lithium UPS Architecture

The PET1103+Li 3kVA lithium UPS addresses power anomalies through online double-conversion engineering paired with a 48V lithium iron phosphate (LiFePO4) energy storage matrix.

The system converts AC power to DC and back to AC. This decouples connected PCs from grid fluctuations and delivers a continuous pure sine wave output with 0 ms transfer time.

For professional users, a 3kVA lithium UPS with online double conversion provides higher protection by converting incoming AC power into DC and reconstructing a clean AC output continuously.

The PET1103+Li solves these challenges by combining:

  • 48V lithium battery technology
  • Online double conversion architecture
  • High power density design
  • Intelligent battery management
  • Long service life energy storage
Feature / MetricLegacy 3kVA VRLA UPSPET1103+Li 3kVA Lithium UPSUser Operational Impact
Battery Lifespan2–3 Years10+ Years3x to 4x longer operational life; eliminates frequent battery swaps
Cycle Life (80% DoD)300 – 500 Cycles6,000+ CyclesResilient against daily cycling and frequent micro-outages
Transfer Time4ms – 10ms (Line-Interactive)0 ms (Online Double Conversion)Guarantees zero crash/reboot on sensitive Active PFC PC power supplies
Weight & Footprint~15 kg – 25kg (Heavy)~6.8 kg – 18 kg (Ultra-Light)60% weight reduction; ideal for rack enclosures and desk setups
Recharge Time (to 90%)8 – 12 Hours1.5 – 2.5 HoursRapid recovery between back-to-back grid disruptions
Operating Temp Range20°C to 25°C (Strict)0°C to 40°C (Wide)High resilience to ambient heat in server rooms or workstation bays

Unlike UPS systems using VRLA batteries, this lithium UPS system uses LiFePO4 battery technology. It offers 6,000+ cycles at 80% DoD, charges to 90% in 1.5–2.5 hours, operates from 0°C to 40°C, and requires fewer replacements.

The UPS provides 3000VA/3000W capacity, making it suitable for:

  • High-performance PCs
  • Gaming and professional workstations
  • Graphic design computers
  • Network servers
  • Communication equipment
  • CCTV monitoring systems
  • Industrial control computers

Product Key Features

True Online Double-Conversion Topology

The PET1103+Li functions as a continuous power filter. It rectifies utility AC power to 48V DC to charge the lithium array. A precision inverter generates an AC sine wave with THD < 2% for linear loads. During grid sags or blackouts, the output waveform remains unchanged.

48V LiFePO4 Lithium Battery System

The integrated 48V lithium battery architecture improves reliability and battery performance.

  • Longer backup lifespan
  • Better thermal stability
  • Higher charging efficiency
  • Reduced replacement frequency

This makes it a reliable 48V lithium UPS for PC and network equipment.

Eco Mode & Dynamic Efficiency Tuning

The PET1103+Li achieves 95% efficiency in double-conversion mode and over 98% in ECO mode. It minimizes heat dissipation and active cooling overhead and lowers energy consumption in continuous operating environments.

Intelligent Charging Management for Longer Battery Life

The built-in intelligent charging system supports:

  • High-current rapid charging algorithms
  • Adjustable charging current
  • Adjustable charging mode through LCD panel
  • Battery protection management

This helps reduce charging time after power recovery and improves overall battery utilization.

Intelligent Battery Management System (BMS)

An integrated industrial BMS monitors cell-level voltages, currents, state-of-charge (SoC), state-of-health (SoH), and temperatures in real time. The BMS balances cells during charge cycles and prevents overcharge, over-discharge, short circuits, and thermal stress.

Generator Compatible Design

PET1103+Li supports generator input, making it suitable for areas with unstable grids.

Applications include:

  • Remote offices
  • Industrial sites
  • Telecom locations
  • Backup power systems

Communication Protocol Compatibility

The UPS inverter and BMS exchange data via RS485. Protocols include Pylontech (RS485 and CANbus). The system reports per‑cell voltage, per‑cell temperature, SoC, and alarm flags every 1 second.

Intelligent LCD Monitoring System

The UPS features an advanced LCD interface providing real-time information:

  • Input voltage
  • Output voltage
  • Battery status
  • Load percentage
  • Operating mode
  • Fault information

Users can easily monitor UPS operation without additional software.

The Power Protection Challenge for Modern PCs and IT Equipment

Technical Specifications

General Specifications

ParameterSpecification
ModelPET1103+Li
Capacity3000VA / 3000W
TopologyOnline Double Conversion
PhaseSingle Phase
Form FactorTower
Dimension (D×W×H)395×145×222 mm
Net Weight6.8 kg

Input and Output Performance

ParameterSpecification
Input Voltage RangeNominal Voltage ±15%
Frequency Range50Hz: 44-56Hz / 60Hz:54-66Hz
Input Power Factor≥0.99
Input THDi<6%
Output Voltage208/220/230/240VAC Selectable
Voltage Regulation±1% (Battery Mode)
Output WaveformPure Sine Wave
Transfer Time0ms
Battery Frequency Accuracy50Hz/60Hz ±0.1%
Crest Factor3:1

Battery and Communication

ParameterSpecification
Battery TypeLiFePO4 Lithium / Lead Acid
Nominal Battery Voltage48VDC (51.2VDC LiFePO4)
Charging Current5A Default, Adjustable 1-30A
Charging ModeCC/Floating or CC/CV/Floating
Battery ProtectionOver-charge, Over-discharge, Over-current, Short Circuit, Temperature Protection
Communication PortsUSB / RS232 / RS485
Smart SlotSNMP / Dry Contact Optional
BMS ProtocolPylontech RS485 & CANbus

Lithium UPS Detail

Single Phase 2kVA-3KVA Online Lithium Battery UPS Rear

1. External Battery Connector2. Emergency Power Off(Option)3. RS485 Port for BMS
4. USB Port5. AC Output Sockets6. Grounding
7. Intelligent Slot(for SNMP Card or AS400 Dry Contact)8. Input Circuit Breaker9. AC Input Terminal

Application Scenarios

Professional Computing Environment

For companies using expensive computers, CAD workstations, medical computers, and data processing systems, stable power is essential.

PET1103+Li protects:

  • CPU and workstation hardware
  • Storage devices
  • Monitors
  • Network switches
  • External equipment

Enterprise Server Backup

Provides clean, regulated online power for mission-critical blade servers, switches, and storage systems (NAS/SAN).

Healthcare & Medical IT

Safeguards lab automation systems, electronic health record (EHR) workstations, and imaging equipment against micro-outages.

Security Monitoring Systems

CCTV systems and surveillance servers must operate continuously.

The lithium UPS ensures:

  • 24/7 monitoring availability
  • Protection against power interruptions
  • Stable operation of DVR/NVR systems

Frequently Asked Questions (FAQ)

What makes a 3kVA lithium UPS superior to a traditional lead-acid UPS for PC setups?

A 3kVA lithium UPS offers up to 3x longer battery life (10+ years), faster recharge rates (under 2.5 hours), 60% lower weight, and higher cycle endurance (3,000+ cycles) compared to lead-acid models. When combined with online double-conversion topology, it provides continuous clean energy with zero transfer time lithium power supply performance, ensuring high-power PCs with active PFC power supplies do not crash.

How does the zero transfer time (0 ms) benefit sensitive computer hardware?

Modern PC power supplies equipped with Active Power Factor Correction (PFC) can trip during the micro-delay (4–10 ms) typical of line-interactive UPS systems. The PET1103+Li provides a constant online double-conversion stream where the inverter directly powers the PC at all times, making grid disconnects completely invisible to connected devices.

Is LiFePO4 battery chemistry safe for office and home workstation environments?

Yes. Lithium Iron Phosphate (LiFePO4) is the safest commercial lithium-ion chemistry available. It features an elevated thermal runaway threshold, eliminates fire risk under puncture or overcharge conditions, and operates alongside an integrated battery management system (BMS) to monitor voltage, current, and temperature parameters constantly.

What is a 3kVA lithium UPS?

A 3kVA lithium UPS is an uninterruptible power supply with a 3000VA capacity that uses lithium battery technology instead of traditional lead-acid batteries. It provides longer battery life, faster charging, and improved energy efficiency.

How long can a 3kVA lithium UPS provide backup power?

Backup time depends on connected load power consumption and battery configuration. Lower loads receive longer runtime, while higher loads reduce backup duration.

Can PET1103+Li work with generators?

Yes. PET1103+Li supports generator compatibility, making it suitable for regions with unstable electricity supply.

The Articles You may Like

MODELPET1103+Li
CAPACITY3000VA/3000W
Form FactorTower Type
Size, D X W X H (mm)395×145×222
Net Weight (kgs)6.8
INPUT
Low Line Transfer176Vac (Load ≥100%); 176–110Vac (Load 100%–50%); 110Vac (Load ≤50%)
Low Line RecoveryLow transfer voltage + 10 V
High Line Transfer300 Vac ±5%
High Line Recovery290 Vac ±5%
Frequency Range50Hz:44-56Hz or 60Hz: 54-66Hz
PhaseSingle Phase, L+N+PE
Power Factor≧ 0.99 @ nominal voltage (input voltage)
Harmonic Distortion(THDi)< 6%
OUTPUT
Output Voltage208/220/230/240VAC (Selectable)
AC Voltage Regulation± 1% (Batt. Mode)
Frequency Range(AC Mode)Synchronized to Mains
Frequency Range (Batt. Mode)50Hz or 60Hz ± 0.1%
Current Crest Ratio3:1
Harmonic Distortion(THDv)<3% THD (Linear Load), <6% THD (Non-linear Load)
Transfer TimeAC to Battery0ms
Battery to AC0ms
Inverter to Bypass4ms
WaveformPure Sine Wave
Overload CapacityAC Mode:                                             Battery Mode:
30mins @102%-110% load                1min @102%-110% load
10mins @110%-130% load                 10sec @110%-130% load
30sec @130%-150% load                    3sec @130%-150% load
200ms @>150% load                          200ms @>150% load
EFFICIENCY
AC Mode> 95%
Battery Mode> 90%
BATTERY
Battery TypeLiFePO4 Lithium / Lead-Acid
Nominal Battery Voltage48VDC (51.2VDC for LiFePO4)
Charging Current5A(Default),1A-30A
Charging Voltage56.4VDC (14.1V * N)
Charging Algorithm2-stage (CC/Floating) or 3-stage (CC/CV/Floating)
BMS ProtectionOver-charge, Over-discharge, Over-current, Short-circuit, Over-temp, Under-temp
Integrated FunctionsAuto Restart, Self-Test Function, Smart Battery Management
ECO
Input Voltage RangeNominal Voltage ± 15%
Input Frequency Range50Hz / 60Hz ± 4Hz
ENVIRONMENT
Ambient Temperature0°C – 40°C
Operation Humidity20%-95% (Non-condensing)
Storage Temperature-15~60℃ (Excluding battery)
Altitude1000 m (derate for higher altitudes up to 4000 m)
Noise LevelLess than 50dBA @ 1 Meter
COMMUNICATION
Communication InterfaceUSB, RS232, RS485
BMS Protocol SupportNative support for Pylontech RS485 and CANbus protocols
Expansion SlotSmart Slot for optional SNMP / Dry Contact card
Prostar 150x40
Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.