Hybrid Solar Inverter 5KW | 48Vdc | 80A MPPT Solar Charger | PV Voltage Range: 120VDC ~430VDC
Prostar PIS5K 48v mppt 450v pv pure sine wave hybrid 5kva solar inverter 5000w is equipped with MPPT solar charger, it can maximize and regulate DC power from the solar array for the charging the battery bank.
Its comprehensive LCD display offers user-configurable and easy-accessible button operation such as battery charging current, AC/Solar charger priority, and acceptable input voltage based on different applications.
Hybrid 5kva solar inverter max. PV array open circuit voltage can reach 450V, and MPPT voltage range is 120V-430V, which can help the users make full use of solar energy. It also can keep supplying power to the loads from PV energy or the grid without battery connected.
1.LCD display 9.AC input connectors
2.AC indicator 10.RS-232 communication port
3.Inverter indicator 11.USB communication port
4.Charging indicator 12.Power ON/OFF
5.Fault indicator 13.Parallel communication port (optional)
6.Function buttons 14.Battery connectors
7.Circuit breaker 15.PV input connectors
8.AC output connectors
Built-in MPPT solar charge controller
Choose your solar inverter in best running way, including working without battery.
Off grid solar inverter 5000w is compatible with Lithium Batteries, but you should do some setting for solar inverter, like: select battery type to LI, config battery charging voltage and end of discharge voltage.
Easily connect WIFI kit for remote monitoring
Parallel function to increasing capacity, max. capacity 45KW.
How many solar panels for 5KVA Solar System?
When selecting proper PV modules, please be sure to consider below parameters:
Model | 3KW | 5KW |
Battery Voltage | 24VDC | 48VDC |
Max. PV Array Open Circuit Voltage | 450VDC | |
PV Array MPPT Voltage Range | 120VDC – 430VDC |
Take 450Wp PV module as an example. After considering above two parameters, the recommended module configurations are listed as below table.
PV module specification (reference)
– 450Wp -Vmp: 33.91V -Imp: 13.27A -Voc: 41.18V -Isc: 13.85A |
SOLAR INPUT
(Min. in serial: 5 pcs; Max. in serial:10 pcs ) |
No. of PV module | Total of Power |
5 pcs in serial | 5 pcs | 2250W | |
6 pcs in serial | 6 pcs | 2700W | |
8 pcs in serial | 8 pcs | 3600W | |
10 pcs in serial | 10 pcs | 4500W | |
6 pcs in serial and 2 groups in parallel | 12 pcs | 5400W |
Model | PIS5K |
PHASE | 1-phase in/1-phase out |
RATED POWER | 5000VA / 5000W |
Parallel Capability | Yes, Max. 9 units |
Dimension WxHxD (mm) |
300x453x120 |
Net Weight (kgs) | 7.5 |
INPUT | |
Voltage | 208VAC/220 VAC/230 VAC/240 VAC |
Selectable Voltage Range | 170-280 VAC (For Personal Computers) |
90-280 VAC (For Home Appliances) | |
Rated Frequency | 50 Hz/60 Hz (Auto sensing) |
Frequency Range | 40Hz-70Hz |
Power Factor | ≥ 0.99 |
OUTPUT | |
AC Voltage Regulation (Batt. Mode) |
208VAC/220 VAC/230 VAC/240 VAC ± 5% |
Surge Power | 10000VA |
Harmonic Distortion | ≤3% (Linear Load), ≤5% (Non-Linear Load) |
Efficiency (Peak) | 94% |
Transfer Time | 10 ms (For Personal Computers); 10 ms (For Home Appliances) |
Waveform | Pure sine wave |
Overload Capacity | 1 min @102%-110% load 10s @110%-130% load 3s @130%-150% load 200ms @>150% load |
BATTERY | |
Battery Voltage | 48 VDC |
Floating Charge Voltage | 54 VDC |
Overcharge Protection | 62 VDC |
SOLAR CHARGER & AC CHARGER | |
Maximum PV Array Power | 5500W |
MPPT Range @ Operating Voltage | 120VDC ~430VDC |
Max. PV Array Open Circuit Voltage | 450VDC |
Maximum Solar Charge Current | 80A |
Maximum AC Charge Current | 2A – 80A (Adjustable) |
Maximum Charge Current | 80A |
SYSTEM | |
Communication Interface | USB, RS232 |
Standby Power Consumption | <60 W |
OPERATING ENVIRONMENT | |
Humidity | 5% to 95% Relative Humidity(Non-condensing) |
Operating Temperature | 0°C to 55°C |
Storage Temperature | -15°C to 60°C |
You must be logged in to post a comment.