Prostar industrial grade single phase online UPS 1KVA – 3KVA

Prostar Highly available industrial grade single phase online UPS 1KVA - 3KVA features redundant and scalable double-conversion on-line power protection.

SKU: SU1K - SU3K Category:

Prostar 6000 Series low frequency online UPS has been designed as combined advanced IGBT technology with hi-frequency wider-modulated technology (PWM), Prostar industrial grade single phase online UPS 1KVA – 3KVA, which make customer could obtain hi-quality power output and optimized efficiency under each operation load. And the advanced modular design to reduce the average time to repair (MTTR), and the best maintenance.It also with the most advanced phase-balanced technology, and it features best stability, even if loss-phase, it could still operate at normal condition, so it’s suitable for any worse power supply. Double conversion, pure sine wave output line design could supply the low-distortion pure sine wave power, so it can provide the best power protection to the users’ equipment. And with the isolated output transformer, which ensure that the entire the isolation of the load and public electric.

    Request Product Price


    * Required

    Model SU1K SU2K SU3K SU1KB SU2KB SU3KB
    Capacity 1KVA/0.8KW 2KVA/1.6KW 3KVA/2.4KW 1KVA/0.8KW 2KVA/1.6KW 3KVA/2.4KW
    Noise 48dB~54dB(Distance 1 Meter)
    Dimension(WxDxH mm) 215x550x500 230x570x520
    Weight(Kgs) 34 35 36 52 54 61
    INPUT
    Voltage Single Phases Two Wires + G, 110Vac/120Vac/128Vac/220Vac/230Vac/240Vac ± 25%
    Frequency 50Hz/60Hz±10%
    Power Factor ≥0.91
    OUTPUT
    Voltage Single Phases Two Wires + G, 110Vac/120Vac/128Vac/220Vac/230Vac/240Vac ± 1%
    Frequency 50Hz/60Hz±0.05%
    Harmonic Distortion Linear load<3%, Non-linear load<5%
    Overload Capacity 110%≥300Min, 125%≥10Min, 150%≥1Min
    Crest Factor 3:1
    Wave Form Pure sine wave
    Transfer Time 0ms
    BATTERY
    Type Support VRLA Battery
    D.C. Voltage 192Vdc
    Battery Number 16Pcs
    Battery Capacity 12V4.5AH
    Max. Charging Current 0.2AxC10
    Charging Time(Standard) 12hours
    SYSTEM
    Protection Input over-voltage, under-voltage; output overload, shortcircuit; Inverter over-temperature; Battery under-voltage,over-voltage
    IP Protection IP20
    Parallel Mode N+1 can be in parallel with differenct power capacity
    Software Interface Windows9x,2000,NT,ME,XP,Linux,Novell,Macosx,NT4.0
    Meantime Between Failures 300,000Hours
    ENVIRONMENT
    Operating Temperature 0℃ to 40℃
    Humidity 0~95% (non-condensing)
    Altitude <1000m (with increase of 100m,it will reduce output of 1%) max. 4000m
    Storage Temperature -15℃ to 50℃
    MANAGEMENT
    Communication Interface RS232
    SNMP Power managemetn from SNMP manager and web browser