Hybrid solar inverter | 10KW | 48VDC |380Vac/400Vac/415Vac | Feed power into the grid
Prostar PSH-10KP best pure sine wave 3 phase hybrid solar inverter 10kw 48v combines solar system, AC utility, and battery power source to supply continuous power. It is self-consumption and feed power into the grid.
PSH-10KP 48v 3 phase hybrid solar inverter 10kw can run without battery backup. It is suitable for remote areas where the cost of the utility bill is too high or emergency usage when utility is not stable.
1. PV connectors 10. Operation buttons
2. AC Grid connectors 11. Dry contact
3. Battery connectors 12. Battery thermal sensor
4. AC output connectors 13. EPO
5. RS-232 communication port 14. AC circuit breaker
6. USB communication port 15. DC Switch
7. Intelligent slot 16. Relay control port
8. Grounding 17. Parallel communication port
9. LCD display panel 18. Current sharing port
This hybrid PV inverter can provide power to connected loads by utilizing PV power, utility power and battery power.
Keep the cables between your inverter and batteries as short as possible. This will help your batteries perform their best and keep the unit’s signal clean. The cables that come with the inverter are “rated” or good for up to six ft. If you plan on going over six ft., drop down to a larger gauge cable. Please call us if you are still unsure. This is pretty important stuff that should NOT be overlooked. If the cables between your battery and inverter get hot while under heavy load, then you should use heavier cables.
Yes, no problem. If cables need to be run, it is best to keep the unit as close as possible to the batteries. Use extension cords on the output side (Vac output) rather than extending the VDC cables. Tip: Contractors often need to mount the inverter in the back of their trucks. In a case like this it would be best to mount a secondary battery near the inverter and wire it to the primary truck battery. Vac extension cords should not exceed 200 feet or you will have signal loss.
Most of our customers prefer to use deep cycle marine batteries with their inverters. A few advantages are:
☑ Delivers higher peak amps faster than conventional batteries
☑ Provides up to twice the life of conventional batteries
☑ More consistent voltage across the discharge curve
☑ Superior cold and hot weather performance vs. conventional batteries
Model | PSH-10KP |
PHASE | 3-phase in/3-phase out |
Max. PV INPUT POWER | 14850W |
Rated Output Power | 10000W |
Maximum Charging Power | 9600W |
Dimension, D x W x H (mm) | 168 x 500 x 622 |
Net weight (kgs) | 40 |
GRID-TIE OPERATION | |
PV INPUT (DC) | |
Nominal DC Voltage/Max. DC Voltage | 720VDC/900VDC |
Start-up Voltage/Initial Feeding Voltage | 320VDC/350VDC |
MPP Voltage Range | 400VDC~800VDC |
Number of MPP Trackers/Max. Input Current | 2/2×18.6A |
GRID OUTPUT (AC) | |
Nominal Output Voltage | 230VAC (P-N) / 400VAC (P-P) |
Output Voltage Range | 184VAC – 265VAC* per phase |
Nominal Output Current | 14.5A per phase |
Power Factor | >0.99 |
EFFICIENCY | |
Maximum Conversion Efficiency (DC/AC) | 96% |
European Efficiency@Vnominal | 95% |
OFF-GRID OPERATION | |
AC INPUT | |
AC start-up Voltage / Auto Restart Voltage | 120VAC – 140VAC per phase/180 VAC per phase |
Acceptable Input Voltage Range | 170VAC – 280VAC per phase |
Max. AC Input Current | 40A |
PV INPUT (DC) | |
Max. DC Voltage | 900VDC |
MPP Voltage Range | 400VDC~800VDC |
Number of MPP Trackers/Max. Input Current | 2/2×18.6A |
BATTERY Mode Output (AC) | |
Nominal Output Voltage | 230VAC (P-N) / 400 VAC (P-P) |
Output Waveform | Pure Sine Wave |
Efficiency (DC to AC) | 91% |
HYBRID OPERATION | |
PV INPUT (DC) | |
Nominal DC Voltage/Max. DC Voltage | 720VDC / 900VDC |
Start-up Voltage/Initial Feeding Voltage | 320VDC / 350VDC |
MPP Voltage Range | 400VDC~800VDC |
Number of MPP Trackers/Max. Input Current | 2/2×18.6A |
GRID OUTOUT (AC) | |
Nominal Output Voltage | 230VAC (P-N) / 400 VAC (P-P) |
Output Voltage Range | 184VAC – 264.5 VAC* per phase |
Nominal Output Current | 14.5A per phase |
AC INPUT | |
AC Start-up Voltage/Auto Restart Voltage | 120VAC -140VAC per phase/ 180 VAC per phase |
Acceptable Input Voltage Range | 170VAC – 280VAC per phase |
Max. AC Input Current | 40A |
BATTERY MODE OUTPUT (AC) | |
Nominal Output Voltage | 230VAC (P-N) / 400 VAC(P-P) |
Efficiency (DC to AC) | 91% |
BATTERY& CHARGER | |
Nominal DC Voltage | 48VDC |
Max. Charging Current | Default 60A, 10A-200A (Adjustable) |
INTERFACE | |
Communication Port | RS-232/USB and CAN Interface |
Intelligent Slot | Optional SNMP, Modbus and AS-400 cards available |
ENVIRONMENT | |
Humidity | 0~90% RH (Non-condensing) |
Operating Temperature | -10 to 55 °C |
Altitude | 0-1000 m** |
*These figures may vary depending on different AC voltage and country requirements.
**Power derating 1% every 100m when altitude is over 1000m.